Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 1996 |
Principal Product | Shrimp & Catfish |
NAICS | n/a |
SIC | 2092 - Fresh Or Frozen Prepared Fish |
Sales | $10,000,000-$50,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 32,600 |
Annual Production | 4,300,000 Pounds |
Production Hrs. Annual | 2,280 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $89,064 | 1,570,047 | kWh | $0.06 |
Electricity Demand | $21,769 | 7,063 | kW-months/year | $3.08 |
Electricity Fees | $3,519 | - | $ | - |
TOTAL ENERGY COSTS | $194,552 | |||
RECOMMENDED SAVINGS* | $114,418 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $99,948 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | By-product Production | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $95,600 Cost: $1,500 |
- | - | - | - | - | - | $80,200 | 764,000 | $15,400 | - |
- - kWh |
- - kW-months/year |
- - $ |
$80,200 764,000 lb |
$15,400 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $14,320 Cost: $14,320 |
- | - | $14,320 | 7,030 | - | - | - | - | - | - |
- - kWh |
$14,320 7,030 kW-months/year |
- - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $150 Cost: $180 |
$70 | 1,465 | $80 | 13 | - | - | - | - | - | - |
$70 1,465 kWh |
$80 13 kW-months/year |
- - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $2,250 Cost: $2,370 |
- | - | $2,250 | 360 | - | - | - | - | - | - |
- - kWh |
$2,250 360 kW-months/year |
- - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $950 Cost: $470 |
$550 | 11,430 | $400 | 65 | - | - | - | - | - | - |
$550 11,430 kWh |
$400 65 kW-months/year |
- - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8123 PAY UTILITY BILLS ON TIME |
Savings: $903 Cost: - |
- | - | - | - | $903 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$903 - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.8112 COMBINE UTILITY METERS |
Savings: $245 Cost: - |
- | - | - | - | $245 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$245 - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $114,418 Cost: $18,840 |
$620 | 12,895 | $17,050 | 7,468 | $1,148 | - | $80,200 | 764,000 | $15,400 | - | $620 12,895 kWh |
$17,050 7,468 kW-months/year |
$1,148 - $ |
$80,200 764,000 lb |
$15,400 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $99,948 Cost: $4,340 |
$550 | 11,430 | $2,650 | 425 | $1,148 | - | $80,200 | 764,000 | $15,400 | - | $550 11,430 kWh |
$2,650 425 kW-months/year |
$1,148 - $ |
$80,200 764,000 lb |
$15,400 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | By-product Production | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | By-product Production |