IAC logo
IAC Assessment: CI0007
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CI0007
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of California, Irvine
Assessment Year 2023
Principal Product PCBA and Electro-Mechanical Products
NAICS 334418 - Printed Circuit Assembly (Electronic Assembly) Manufacturing
SIC 3679 - Electronic Components, Nec
Sales $10,000,000-$50,000,000
# of Employees 135
Plant Area (Sq.Ft.) 65,000
Annual Production 40,000,000 Pieces
Production Hrs. Annual 2,000
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $108,582 891,524 kWh $0.12
Electricity Demand $117,532 3,908 kW-months/year $30.07
Natural Gas $576 19 MMBtu $30.16
TOTAL ENERGY COSTS $226,690
RECOMMENDED SAVINGS* $75,791 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$52,065
Cost:
-
$52,065 427,481 - - $52,065
427,481
kWh
-
-
kW-months/year
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$9,880
Cost:
$300
$7,880 64,696 $2,000 67 $7,880
64,696
kWh
$2,000
67
kW-months/year
03: 2.7493 USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES Savings:
$4,072
Cost:
$15,610
$4,072 33,431 - - $4,072
33,431
kWh
-
-
kW-months/year
04: 2.7316 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN Savings:
$3,248
Cost:
$4,500
$1,431 11,750 $1,817 60 $1,431
11,750
kWh
$1,817
60
kW-months/year
05: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$2,887
Cost:
$50
- - $2,887 96 -
-
kWh
$2,887
96
kW-months/year
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,123
Cost:
$836
$1,888 15,504 $235 8 $1,888
15,504
kWh
$235
8
kW-months/year
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$853
Cost:
-
$636 5,221 $217 7 $636
5,221
kWh
$217
7
kW-months/year
08: 2.6223 SCHEDULE USE OF ELEVATORS TO CONSERVE ENERGY Savings:
$663
Cost:
-
$663 5,445 - - $663
5,445
kWh
-
-
kW-months/year
TOTAL RECOMMENDED Savings:
$75,791
Cost:
$21,296
$68,635 563,528 $7,156 238 $68,635
563,528
kWh
$7,156
238
kW-months/year
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand