Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 1996 |
Principal Product | Meat and seafood |
NAICS | n/a |
SIC | 2010 - |
Sales | $10,000,000-$50,000,000 |
# of Employees | 80 |
Plant Area (Sq.Ft.) | 70,000 |
Annual Production | 5,000,000 Pounds |
Production Hrs. Annual | 2,000 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $107,375 | 3,342,321 | kWh | $0.03 |
Electricity Demand | $61,423 | 7,329 | kW-months/year | $8.38 |
Fuel Oil #2 | $3,300 | 840 | MMBtu | $3.93 |
TOTAL ENERGY COSTS | $186,073 | |||
RECOMMENDED SAVINGS* | $11,029 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $10,198 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #2 | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Fuel Oil #2 | Water Disposal | Solid Waste (non-haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $69 Cost: $112 |
$31 | 879 | $38 | 5 | - | - | - | - | - | - | - | - |
$31 879 kWh |
$38 5 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $541 Cost: - |
- | - | $541 | 65 | - | - | - | - | - | - | - | - |
- - kWh |
$541 65 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $495 Cost: $900 |
$156 | 4,689 | $237 | 28 | - | - | - | - | - | - | $102 | - |
$156 4,689 kWh |
$237 28 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
$102 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $915 Cost: $2,478 |
$365 | 12,896 | $550 | 66 | - | - | - | - | - | - | - | - |
$365 12,896 kWh |
$550 66 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $831 Cost: $2,475 |
$74 | 2,052 | $757 | 91 | - | - | - | - | - | - | - | - |
$74 2,052 kWh |
$757 91 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $223 Cost: $150 |
$90 | 2,638 | $133 | 16 | - | - | - | - | - | - | - | - |
$90 2,638 kWh |
$133 16 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $107 Cost: $600 |
- | - | - | - | $107 | 27 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$107 27 MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4151 MINIMIZE WATER USAGE |
Savings: $1,104 Cost: $900 |
- | - | - | - | $718 | 184 | $386 | 187,500 | - | - | - | - |
- - kWh |
- - kW-months/year |
$718 184 MMBtu |
$386 187,500 Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.4156 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE |
Savings: $494 Cost: $600 |
- | - | - | - | - | - | $494 | 240,000 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$494 240,000 Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $6,250 Cost: $7,000 |
- | - | - | - | - | - | - | - | $6,250 | 500,000 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$6,250 500,000 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $11,029 Cost: $15,215 |
$716 | 23,154 | $2,256 | 271 | $825 | 211 | $880 | 427,500 | $6,250 | 500,000 | $102 | - | $716 23,154 kWh |
$2,256 271 kW-months/year |
$825 211 MMBtu |
$880 427,500 Tgal |
$6,250 500,000 lb |
$102 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $10,198 Cost: $12,740 |
$642 | 21,102 | $1,499 | 180 | $825 | 211 | $880 | 427,500 | $6,250 | 500,000 | $102 | - | $642 21,102 kWh |
$1,499 180 kW-months/year |
$825 211 MMBtu |
$880 427,500 Tgal |
$6,250 500,000 lb |
$102 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #2 | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Fuel Oil #2 | Water Disposal | Solid Waste (non-haz) | Personnel Changes |