Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2024 |
Principal Product | Broad Band Communication Products |
NAICS | 334417 - Electronic Connector Manufacturing |
SIC | 3663 - Radio & Tv Communications Equipment |
Sales | $100,000,000-$500,000,000 |
# of Employees | 315 |
Plant Area (Sq.Ft.) | 80,000 |
Annual Production | 940,000 Units |
Production Hrs. Annual | 6,240 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $444,636 | 5,909,053 | kWh | $0.08 |
Electricity Demand | $154,058 | 12,101 | kW-months/year | $12.73 |
Electricity Fees | $16,101 | - | $ | - |
Natural Gas | $42,764 | 5,843 | MMBtu | $7.32 |
Other Gas | $1,220 | 1 | MMBtu | $1,220.07 |
TOTAL ENERGY COSTS | $658,778 | |||
RECOMMENDED SAVINGS* | $229,515 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $616 Cost: - |
- | - | - | - | - | - | $616 | 84 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$616 84 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $2,970 Cost: - |
- | - | $2,970 | 233 | - | - | - | - | - | - | - | - |
- - kWh |
$2,970 233 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $7,702 Cost: - |
- | - | $7,702 | 605 | - | - | - | - | - | - | - | - |
- - kWh |
$7,702 605 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,953 Cost: - |
$1,953 | 26,045 | - | - | - | - | - | - | - | - | - | - |
$1,953 26,045 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $813 Cost: $105 |
- | - | - | - | $813 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$813 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,067 Cost: $135 |
$1,067 | 14,222 | - | - | - | - | - | - | - | - | - | - |
$1,067 14,222 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $9,403 Cost: $8,340 |
$5,653 | 75,378 | $2,394 | 188 | - | - | - | - | - | - | $1,356 | - |
$5,653 75,378 kWh |
$2,394 188 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
$1,356 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $444 Cost: $544 |
$226 | 3,013 | $52 | 4 | - | - | - | - | $166 | - | - | - |
$226 3,013 kWh |
$52 4 kW-months/year |
- - $ |
- - MMBtu |
$166 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $690 Cost: $1,542 |
$690 | 9,198 | - | - | - | - | - | - | - | - | - | - |
$690 9,198 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7234 USE HEAT PUMP FOR SPACE CONDITIONING |
Savings: $129,448 Cost: $632,250 |
$(-150,789) | (-2,010,528) | - | - | - | - | $280,237 | 38,284 | - | - | - | - |
$(-150,789) (-2,010,528) kWh |
- - kW-months/year |
- - $ |
$280,237 38,284 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $74,409 Cost: $461,768 |
$74,409 | 992,124 | - | - | - | - | - | - | - | - | - | - |
$74,409 992,124 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $229,515 Cost: $1,104,684 |
$(-66,790) | (-890,548) | $13,117 | 1,030 | $813 | - | $280,853 | 38,368 | $166 | - | $1,356 | - | $(-66,790) (-890,548) kWh |
$13,117 1,030 kW-months/year |
$813 - $ |
$280,853 38,368 MMBtu |
$166 - $ |
$1,356 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Administrative Changes |