Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1990
Principal Product HYDRAULIC FLUID PUMPS
NAICS n/a
SIC 3594 - Fluid Power Pumps And Motors
Sales $10,000,000-$50,000,000
# of Employees 270
Plant Area (Sq.Ft.) 0
Annual Production 100,000 Pieces
Production Hrs. Annual 6,000
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $207,956 4,074,443 kWh $0.05
Natural Gas $58,926 22,363 MMBtu $2.63
TOTAL ENERGY COSTS $266,882
RECOMMENDED SAVINGS* $38,469 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.3135 SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS Savings:
$19,921
Cost:
-
$19,921 - - - $19,921
-
kWh
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$7,064
Cost:
$12,726
$7,064 138,335 - - $7,064
138,335
kWh
-
-
MMBtu
03: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$2,784
Cost:
-
$2,784 - - - $2,784
-
kWh
-
-
MMBtu
04: 2.6232 INSTALL SET-BACK TIMERS Savings:
$1,952
Cost:
$1,000
$1,952 38,394 - - $1,952
38,394
kWh
-
-
MMBtu
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,725
Cost:
$3,750
$1,725 33,705 - - $1,725
33,705
kWh
-
-
MMBtu
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,725
Cost:
-
$1,725 33,705 - - $1,725
33,705
kWh
-
-
MMBtu
07: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$1,709
Cost:
$500
- - $1,709 650 -
-
kWh
$1,709
650
MMBtu
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$1,107
Cost:
$1,000
- - $1,107 421 -
-
kWh
$1,107
421
MMBtu
09: 2.7494 INSTALL STORM WINDOWS AND DOORS Savings:
$482
Cost:
$1,440
- - $482 183 -
-
kWh
$482
183
MMBtu
TOTAL RECOMMENDED Savings:
$38,469
Cost:
$20,416
$35,171 244,139 $3,298 1,254 $35,171
244,139
kWh
$3,298
1,254
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas