Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
108
matching recommendationsNAICS | 21232 | Sand, Gravel, Clay, and Ceramic and Refractory Minerals Mining and Quarrying |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0781 # 04 Y:2023 | 04 | 2023 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $486,797 | $4,030,000 | Not Implemented |
OR0781 # 03 Y:2023 | 03 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $618 | $2,576 | Implemented |
OR0781 # 02 Y:2023 | 02 | 2023 | OPTIMIZE PLANT POWER FACTOR | $3,665 | $20,839 | Not Implemented |
OR0781 # 01 Y:2023 | 01 | 2023 | ELIMINATE/REDUCE AN OPERATION | $112,997 | $116,429 | Not Implemented |
LE0550 # 01 Y:2023 | 01 | 2023 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,663 | $100 | Implemented |
LE0550 # 06 Y:2023 | 06 | 2023 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,500 | $22,000 | Not Implemented |
LE0550 # 07 Y:2023 | 07 | 2023 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $5,791 | $34,566 | Implemented |
LE0550 # 02 Y:2023 | 02 | 2023 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $1,474 | $2,500 | Implemented |
LE0550 # 05 Y:2023 | 05 | 2023 | ELIMINATE A BY-PRODUCT | $85,450 | $350,000 | Implemented |
LE0550 # 03 Y:2023 | 03 | 2023 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,539 | $3,500 | Implemented |
LE0550 # 04 Y:2023 | 04 | 2023 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $299 | $1,150 | Not Implemented |
TT0238 # 01 Y:2020 | 01 | 2020 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $28,385 | $3,500 | Implemented |
TT0238 # 02 Y:2020 | 02 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,091 | $75,890 | Implemented |
TT0238 # 04 Y:2020 | 04 | 2020 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $10,965 | $22,780 | Implemented |
TT0238 # 03 Y:2020 | 03 | 2020 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $13,222 | $25,000 | Not Implemented |
TT0238 # 05 Y:2020 | 05 | 2020 | INCREASE EFFICIENCY OF TRUCKS | $7,291 | $24,565 | Not Implemented |
TT0238 # 06 Y:2020 | 06 | 2020 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $6,836 | $1,500 | Implemented |
TT0238 # 07 Y:2020 | 07 | 2020 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,527 | $350 | Implemented |
TT0238 # 08 Y:2020 | 08 | 2020 | TURN OFF EQUIPMENT WHEN NOT IN USE | $511 | $40 | Implemented |
OR0730 # 01 Y:2019 | 01 | 2019 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $15,651 | $5,000 | Not Implemented |
OR0730 # 02 Y:2019 | 02 | 2019 | MODIFY WORKLOAD | $13,223 | $18,824 | Not Implemented |
OR0730 # 03 Y:2019 | 03 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,201 | $0 | Not Implemented |
OR0730 # 04 Y:2019 | 04 | 2019 | OPTIMIZE PLANT POWER FACTOR | $2,657 | $9,364 | Not Implemented |
OR0730 # 05 Y:2019 | 05 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,030 | $2,058 | Not Implemented |
WM0138 # 06 Y:2019 | 06 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,375 | $11,900 | Implemented |