IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,017

matching recommendations
Reset
NAICS 221 Utilities
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0487 # 03 Y:2014 03 2014 UPGRADE OBSOLETE EQUIPMENT $9,337 $35,560 Implemented
SD0487 # 04 Y:2014 04 2014 REDUCE SCRAP PRODUCTION $4,795 $10,700 Implemented
SD0487 # 05 Y:2014 05 2014 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $3,282 $9,400 Implemented
SD0487 # 06 Y:2014 06 2014 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $2,473 $2,350 Implemented
SF0448 # 01 Y:2014 01 2014 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $5,956 $0 Implemented
SF0448 # 05 Y:2014 05 2014 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,825 $7,952 Implemented
MA0732 # 02 Y:2014 02 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,511 $29,280 Implemented
MA0732 # 03 Y:2014 03 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,880 $15,310 Implemented
MA0731 # 03 Y:2014 03 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,813 $5,000 Implemented
DL0130 # 02 Y:2014 02 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $54,689 $88,625 Implemented
DL0130 # 03 Y:2014 03 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $800 $200 Implemented
DL0130 # 04 Y:2014 04 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,400 $800 Implemented
DL0130 # 05 Y:2014 05 2014 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $3,400 $8,400 Implemented
OR0627 # 01 Y:2014 01 2014 TURN OFF EQUIPMENT WHEN NOT IN USE $28,066 $0 Implemented
OR0627 # 02 Y:2014 02 2014 TURN OFF EQUIPMENT WHEN NOT IN USE $54,087 $0 Implemented
OR0627 # 03 Y:2014 03 2014 CHANGE OPERATING CONDITIONS $30,875 $0 Implemented
OR0627 # 04 Y:2014 04 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $7,799 $1,000 Implemented
OR0627 # 07 Y:2014 07 2014 UPGRADE CONTROLS ON COMPRESSORS $10,323 $17,350 Implemented
OR0627 # 10 Y:2014 10 2014 USE PHOTOCELL CONTROLS $3,741 $7,191 Implemented
OR0627 # 11 Y:2014 11 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,856 $39,597 Implemented
SF0445 # 01 Y:2014 01 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $8,564 $0 Implemented
SF0445 # 02 Y:2014 02 2014 TURN OFF EQUIPMENT WHEN NOT IN USE $2,245 $0 Implemented
SF0445 # 04 Y:2014 04 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,993 $21,342 Implemented
DL0122 # 04 Y:2014 04 2014 INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS $134,000 $150,000 Implemented
MA0722 # 01 Y:2014 01 2014 USE POWER DURING OFF-PEAK PERIODS $11,298 $500 Implemented