Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
55
matching recommendationsNAICS | 2213 | Water, Sewage and Other Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0740 # 05 Y:2021 | 05 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $27,831 | $84,560 | Implemented |
OR0740 # 04 Y:2021 | 04 | 2021 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $39,964 | $60,439 | Implemented |
OR0740 # 03 Y:2021 | 03 | 2021 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $54,988 | $79,709 | Implemented |
OR0740 # 02 Y:2021 | 02 | 2021 | UPGRADE OBSOLETE EQUIPMENT | $68,316 | $149,022 | Not Implemented |
OR0740 # 01 Y:2021 | 01 | 2021 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $69,219 | $8,189 | Implemented |
OR0740 # 07 Y:2021 | 07 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,547 | $3,289 | Implemented |
OR0707 # 02 Y:2018 | 02 | 2018 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,884 | $53,702 | Implemented |
OR0707 # 01 Y:2018 | 01 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $23,086 | $32,488 | Not Implemented |
OR0707 # 04 Y:2018 | 04 | 2018 | REDUCE FLUID FLOW RATES | $6,509 | $7,384 | Implemented |
OR0707 # 06 Y:2018 | 06 | 2018 | IMPROVE COMBUSTION CONTROL CAPABILITY | $1,431 | $5,365 | Implemented |
OR0707 # 05 Y:2018 | 05 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,481 | $19,583 | Implemented |
OR0707 # 03 Y:2018 | 03 | 2018 | INSULATE BARE EQUIPMENT | $7,954 | $8,965 | Implemented |
OR0705 # 01 Y:2018 | 01 | 2018 | UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS | $1,817,773 | $8,000,000 | Implemented |
OR0705 # 02 Y:2018 | 02 | 2018 | IMPROVE COMBUSTION CONTROL CAPABILITY | $6,117 | $13,300 | Not Implemented |
OR0705 # 03 Y:2018 | 03 | 2018 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,640 | $5,820 | Not Implemented |
OR0705 # 04 Y:2018 | 04 | 2018 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $34,519 | $150,000 | Not Implemented |
OR0695 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,343 | $10,981 | Not Implemented |
OR0695 # 02 Y:2017 | 02 | 2017 | USE COLD WASTE WATER TO COOL CHILLER FEED WATER | $13,796 | $30,600 | Not Implemented |
OR0695 # 03 Y:2017 | 03 | 2017 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,279 | $43,386 | Implemented |
OR0648 # 02 Y:2015 | 02 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $25,082 | $17,274 | Not Implemented |
OR0648 # 01 Y:2015 | 01 | 2015 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $16,127 | $9,607 | Implemented |
OR0648 # 03 Y:2015 | 03 | 2015 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,772 | $50 | Implemented |
OR0648 # 04 Y:2015 | 04 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,835 | $9,332 | Not Implemented |
OR0637 # 03 Y:2014 | 03 | 2014 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,677 | $1,971 | Not Implemented |
OR0637 # 02 Y:2014 | 02 | 2014 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $9,404 | $10,529 | Not Implemented |