Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,132
matching recommendationsNAICS | 311 | Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0290 # 04 Y:2009 | 04 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,543 | $750 | Implemented |
LE0290 # 07 Y:2009 | 07 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,267 | $0 | Implemented |
LE0290 # 08 Y:2009 | 08 | 2009 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $1,204 | $2,500 | Implemented |
LE0290 # 09 Y:2009 | 09 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,150 | $2,500 | Implemented |
LE0290 # 10 Y:2009 | 10 | 2009 | INSTALL OCCUPANCY SENSORS | $1,045 | $0 | Implemented |
LE0290 # 12 Y:2009 | 12 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $990 | $2,500 | Implemented |
OK0778 # 01 Y:2009 | 01 | 2009 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $171,482 | $47,731 | Implemented |
OK0778 # 02 Y:2009 | 02 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,464 | $1,266 | Implemented |
OK0778 # 03 Y:2009 | 03 | 2009 | REPAIR AND ELIMINATE STEAM LEAKS | $13,933 | $525 | Implemented |
OK0778 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,111 | $5,417 | Implemented |
OK0778 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $412 | $0 | Implemented |
IA0442 # 03 Y:2009 | 03 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,623 | $25 | Implemented |
AM0560 # 02 Y:2009 | 02 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $17,860 | $25,000 | Implemented |
AM0560 # 03 Y:2009 | 03 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $31,130 | $70,250 | Implemented |
AM0560 # 04 Y:2009 | 04 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $25,120 | $2,500 | Implemented |
AM0560 # 05 Y:2009 | 05 | 2009 | REPAIR OR REPLACE STEAM TRAPS | $16,000 | $1,900 | Implemented |
AM0560 # 06 Y:2009 | 06 | 2009 | INSULATE BARE EQUIPMENT | $10,970 | $2,190 | Implemented |
AM0560 # 07 Y:2009 | 07 | 2009 | USE SYNTHETIC LUBRICANT | $2,715 | $0 | Implemented |
AM0560 # 08 Y:2009 | 08 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,495 | $670 | Implemented |
AM0560 # 09 Y:2009 | 09 | 2009 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $620 | $0 | Implemented |
IC0156 # 01 Y:2009 | 01 | 2009 | ADD AREA LIGHTING SWITCHES | $10,860 | $8,096 | Implemented |
IC0156 # 02 Y:2009 | 02 | 2009 | INSTALL OCCUPANCY SENSORS | $4,252 | $4,247 | Implemented |
IC0156 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,116 | $1,649 | Implemented |
IC0156 # 04 Y:2009 | 04 | 2009 | DISCONNECT BALLASTS | $2,089 | $2,200 | Implemented |
IC0156 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,483 | $29,250 | Implemented |