Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
378
matching recommendationsNAICS | 311 | Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0191 # 01 Y:2004 | 01 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,017 | $0 | Implemented |
SU0191 # 02 Y:2004 | 02 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $382 | $328 | Not Implemented |
SU0191 # 03 Y:2004 | 03 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $19,058 | $25,000 | Implemented |
SU0191 # 04 Y:2004 | 04 | 2004 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $19,254 | $38,185 | Not Implemented |
SU0191 # 05 Y:2004 | 05 | 2004 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,413 | $2,856 | Implemented |
SU0191 # 06 Y:2004 | 06 | 2004 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $3,000 | $7,400 | Not Implemented |
MA0552 # 01 Y:2004 | 01 | 2004 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $93,689 | $21,360 | Not Implemented |
MA0552 # 02 Y:2004 | 02 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,401 | $31,625 | Not Implemented |
MA0552 # 03 Y:2004 | 03 | 2004 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $14,380 | $4,000 | Not Implemented |
MA0552 # 04 Y:2004 | 04 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $7,043 | $4,730 | Not Implemented |
MA0552 # 05 Y:2004 | 05 | 2004 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $5,846 | $17,600 | Implemented |
MA0552 # 06 Y:2004 | 06 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,209 | $1,643 | Not Implemented |
MA0552 # 07 Y:2004 | 07 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,686 | $285 | Not Implemented |
MA0552 # 08 Y:2004 | 08 | 2004 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $428 | $18,000 | Not Implemented |
MA0552 # 09 Y:2004 | 09 | 2004 | INSTALL OCCUPANCY SENSORS | $31,340 | $3,749 | Implemented |
MA0552 # 10 Y:2004 | 10 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,426 | $49,385 | Not Implemented |
SU0184 # 01 Y:2004 | 01 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,982 | $0 | Implemented |
SU0184 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,593 | $1,000 | Implemented |
SU0184 # 03 Y:2004 | 03 | 2004 | INSTALL OCCUPANCY SENSORS | $3,478 | $574 | Implemented |
SU0184 # 04 Y:2004 | 04 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $8,876 | $2,584 | Implemented |
SU0184 # 05 Y:2004 | 05 | 2004 | OPTIMIZE PLANT POWER FACTOR | $5,619 | $2,410 | Implemented |
SU0184 # 06 Y:2004 | 06 | 2004 | USE SYNTHETIC LUBRICANT | $2,480 | $2,000 | Implemented |
SU0184 # 07 Y:2004 | 07 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $15,570 | $26,324 | Not Implemented |
SU0184 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,125 | $15,744 | Implemented |
SU0175 # 01 Y:2004 | 01 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $839 | $0 | Implemented |