Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
347
matching recommendationsNAICS | 311 | Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0457 # 02 Y:2004 | 02 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,140 | $10,000 | Not Implemented |
OR0457 # 03 Y:2004 | 03 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $31,300 | $0 | Implemented |
OR0457 # 04 Y:2004 | 04 | 2004 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $13,100 | $42,000 | Not Implemented |
OR0457 # 05 Y:2004 | 05 | 2004 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $18,900 | $0 | Implemented |
OR0457 # 06 Y:2004 | 06 | 2004 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $2,520 | $300 | Implemented |
OR0442 # 01 Y:2003 | 01 | 2003 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $27,900 | $23,290 | Not Implemented |
OR0442 # 02 Y:2003 | 02 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $21,500 | $11,700 | Implemented |
OR0442 # 03 Y:2003 | 03 | 2003 | USE PHOTOCELL CONTROLS | $11,250 | $1,340 | Not Implemented |
OR0442 # 04 Y:2003 | 04 | 2003 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $7,900 | $0 | Implemented |
OR0442 # 05 Y:2003 | 05 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,470 | $0 | Implemented |
OR0442 # 06 Y:2003 | 06 | 2003 | INSTALL ISOLATION TRANSFORMER ON ADJUSTABLE FREQUENCY DRIVE | $580 | $1,400 | Not Implemented |
OR0441 # 01 Y:2003 | 01 | 2003 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $65,260 | $70,100 | Implemented |
OR0441 # 02 Y:2003 | 02 | 2003 | SHUT OFF STEAM TRAPS ON SUPER HEATED STEAM LINES WHEN NOT IN USE | $18,970 | $2,160 | Implemented |
OR0441 # 03 Y:2003 | 03 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,670 | $985 | Implemented |
OR0441 # 04 Y:2003 | 04 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $18,900 | $10,080 | Implemented |
OR0428 # 01 Y:2003 | 01 | 2003 | COMBINE UTILITY METERS | $3,901 | $7,500 | Not Implemented |
OR0428 # 02 Y:2003 | 02 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $307 | $0 | Implemented |
OR0428 # 03 Y:2003 | 03 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $743 | $26 | Implemented |
OR0428 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $437 | $500 | Implemented |
OR0428 # 05 Y:2003 | 05 | 2003 | INSULATE BARE EQUIPMENT | $742 | $1,320 | Not Implemented |
OR0428 # 06 Y:2003 | 06 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $688 | $2,800 | Not Implemented |
OR0428 # 07 Y:2003 | 07 | 2003 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $400 | $1,970 | Implemented |