Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

123

matching recommendations
Reset
NAICS 311 Food Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0402 # 04 Y:2010 04 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,982 $0 Implemented
NC0402 # 05 Y:2010 05 2010 DEVELOP A REPAIR/REPLACE POLICY $445 $1,454 Implemented
NC0402 # 06 Y:2010 06 2010 COVER OPEN TANKS $3,253 $0 Not Implemented
NC0362 # 01 Y:2007 01 2007 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $43,646 $70,525 Not Implemented
NC0362 # 02 Y:2007 02 2007 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $75,775 $79,525 Not Implemented
NC0362 # 03 Y:2007 03 2007 DEVELOP A REPAIR/REPLACE POLICY $3,512 $3,546 Not Implemented
NC0362 # 04 Y:2007 04 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,160 $50 Not Implemented
NC0362 # 05 Y:2007 05 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $295 $537 Not Implemented
NC0362 # 06 Y:2007 06 2007 MAKE A NEW BY-PRODUCT $655,523 $2,000,000 Not Implemented
NC0312 # 01 Y:2005 01 2005 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $6,776 $6,516 Not Implemented
NC0312 # 02 Y:2005 02 2005 ADJUST BURNERS FOR EFFICIENT OPERATION $1,366 $1,300 Implemented
NC0312 # 03 Y:2005 03 2005 INSTALL / REPAIR INSULATION ON STEAM LINES $2,325 $2,286 Implemented
NC0312 # 04 Y:2005 04 2005 BASE UTILITY CHARGES ON USAGE RATHER THAN AREA OCCUPIED $1,377 $100 Not Implemented
NC0312 # 05 Y:2005 05 2005 REDUCE EXCESSIVE BOILER BLOWDOWN $152 $0 Implemented
NC0312 # 06 Y:2005 06 2005 DEVELOP A REPAIR/REPLACE POLICY $125 $273 Implemented
NC0312 # 07 Y:2005 07 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $169 $321 Implemented
NC0312 # 08 Y:2005 08 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $100 $100 Implemented
NC0312 # 09 Y:2005 09 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $134 $100 Implemented
NC0302 # 01 Y:2004 01 2004 INSTALL DESICCANT HUMIDITY CONTROL SYSTEM $59,627 $136,000 Implemented
NC0302 # 02 Y:2004 02 2004 AVOID FROST FORMATION ON EVAPORATORS $5,926 $19,000 Not Implemented
NC0302 # 03 Y:2004 03 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $953 $100 Implemented
NC0302 # 04 Y:2004 04 2004 ADJUST BURNERS FOR EFFICIENT OPERATION $372 $0 Implemented
NC0302 # 05 Y:2004 05 2004 ADJUST BURNERS FOR EFFICIENT OPERATION $5,988 $0 Implemented