Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

120

matching recommendations
Reset
NAICS 3114 Fruit and Vegetable Preserving and Specialty Food Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0503 # 06 Y:2006 06 2006 INSTALL / REPAIR INSULATION ON STEAM LINES $5,341 $600 Implemented
OR0503 # 07 Y:2006 07 2006 OPTIMIZE PLANT POWER FACTOR $4,700 $18,300 Not Implemented
OR0475 # 01 Y:2005 01 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,030 $6,920 Not Implemented
OR0475 # 02 Y:2005 02 2005 AVOID FROST FORMATION ON EVAPORATORS $6,600 $1,500 Implemented
OR0475 # 03 Y:2005 03 2005 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $3,300 $0 Not Implemented
OR0475 # 04 Y:2005 04 2005 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $9,700 $0 Not Implemented
OR0475 # 05 Y:2005 05 2005 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $920 $0 Not Implemented
OR0475 # 06 Y:2005 06 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $3,920 $0 Implemented
OR0459 # 01 Y:2004 01 2004 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $4,500 $10,500 Not Implemented
OR0459 # 02 Y:2004 02 2004 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $9,750 $300 Implemented
OR0459 # 03 Y:2004 03 2004 UPGRADE CONTROLS ON COMPRESSORS $4,820 $36,600 Implemented
OR0459 # 04 Y:2004 04 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $34,250 $2,000 Implemented
OR0459 # 05 Y:2004 05 2004 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $5,330 $2,825 Implemented
OR0459 # 06 Y:2004 06 2004 OPTIMIZE PLANT POWER FACTOR $2,730 $5,130 Implemented
OR0457 # 01 Y:2004 01 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $24,600 $25,000 Implemented
OR0457 # 02 Y:2004 02 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,140 $10,000 Not Implemented
OR0457 # 03 Y:2004 03 2004 UPGRADE CONTROLS ON COMPRESSORS $31,300 $0 Implemented
OR0457 # 04 Y:2004 04 2004 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $13,100 $42,000 Not Implemented
OR0457 # 05 Y:2004 05 2004 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $18,900 $0 Implemented
OR0457 # 06 Y:2004 06 2004 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $2,520 $300 Implemented