Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
619
matching recommendationsNAICS | 3115 | Dairy Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0394 # 05 Y:2005 | 05 | 2005 | INSTALL AUTOMATIC PACKING EQUIPMENT | $443,040 | $453,047 | Implemented |
UM0272 # 01 Y:2005 | 01 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,828 | $1,000 | Implemented |
UM0272 # 03 Y:2005 | 03 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,631 | $300 | Implemented |
LL0207 # 01 Y:2004 | 01 | 2004 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $36,769 | $16,000 | Implemented |
LL0207 # 02 Y:2004 | 02 | 2004 | INSULATE BARE EQUIPMENT | $34,833 | $7,488 | Implemented |
LL0207 # 05 Y:2004 | 05 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $2,149 | $1,960 | Implemented |
LL0207 # 10 Y:2004 | 10 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $46,500 | $3,150 | Implemented |
SU0197 # 03 Y:2004 | 03 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,966 | $0 | Implemented |
SU0197 # 04 Y:2004 | 04 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,301 | $154 | Implemented |
SU0197 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,462 | $725 | Implemented |
SU0197 # 07 Y:2004 | 07 | 2004 | USE SYNTHETIC LUBRICANT | $2,982 | $1,000 | Implemented |
SU0197 # 09 Y:2004 | 09 | 2004 | OPTIMIZE PLANT POWER FACTOR | $2,001 | $6,941 | Implemented |
WV0305 # 02 Y:2004 | 02 | 2004 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $6,442 | $1,774 | Implemented |
WV0305 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,562 | $221 | Implemented |
WV0305 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,370 | $6,052 | Implemented |
WV0305 # 05 Y:2004 | 05 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,922 | $1,000 | Implemented |
WV0305 # 06 Y:2004 | 06 | 2004 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,458 | $337 | Implemented |
WV0305 # 07 Y:2004 | 07 | 2004 | REPAIR OR REPLACE STEAM TRAPS | $2,040 | $1,870 | Implemented |
WV0305 # 11 Y:2004 | 11 | 2004 | INSULATE BARE EQUIPMENT | $1,275 | $591 | Implemented |
WV0305 # 12 Y:2004 | 12 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $964 | $416 | Implemented |
WV0305 # 13 Y:2004 | 13 | 2004 | USE SYNTHETIC LUBRICANT | $532 | $326 | Implemented |
WV0305 # 14 Y:2004 | 14 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $543 | $174 | Implemented |
SU0191 # 01 Y:2004 | 01 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,017 | $0 | Implemented |
SU0191 # 03 Y:2004 | 03 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $19,058 | $25,000 | Implemented |
SU0191 # 05 Y:2004 | 05 | 2004 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,413 | $2,856 | Implemented |