Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
136
matching recommendationsNAICS | 311513 | Cheese Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0116 # 02 Y:2006 | 02 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $111,472 | $82,700 | Implemented |
LM0116 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $230,613 | $69,350 | Implemented |
LM0116 # 06 Y:2006 | 06 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $260 | $0 | Implemented |
IA0377 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,676 | $172 | Implemented |
IA0377 # 02 Y:2005 | 02 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,951 | $80 | Implemented |
IA0377 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,838 | $4,329 | Implemented |
IA0377 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,602 | $2,146 | Implemented |
IA0377 # 05 Y:2005 | 05 | 2005 | INSTALL OCCUPANCY SENSORS | $1,064 | $1,078 | Implemented |
IA0377 # 06 Y:2005 | 06 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,352 | $1,000 | Implemented |
IA0377 # 08 Y:2005 | 08 | 2005 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,988 | $5,000 | Implemented |
IA0377 # 10 Y:2005 | 10 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $2,898 | $456 | Implemented |
IA0377 # 11 Y:2005 | 11 | 2005 | INSTALL REPLACEMENT DOORS | $725 | $240 | Implemented |
BD0289 # 01 Y:2005 | 01 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,189 | $3,500 | Implemented |
BD0289 # 02 Y:2005 | 02 | 2005 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $4,957 | $0 | Implemented |
BD0289 # 03 Y:2005 | 03 | 2005 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,275 | $6,900 | Implemented |
BD0289 # 05 Y:2005 | 05 | 2005 | INSTALL OCCUPANCY SENSORS | $910 | $1,050 | Implemented |
BD0289 # 07 Y:2005 | 07 | 2005 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $770 | $1,780 | Implemented |
BD0289 # 08 Y:2005 | 08 | 2005 | USE POWER DURING OFF-PEAK PERIODS | $484 | $0 | Implemented |
BD0289 # 09 Y:2005 | 09 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $315 | $576 | Implemented |
BD0289 # 11 Y:2005 | 11 | 2005 | INSTALL AUTOMATIC PACKING EQUIPMENT | $57,600 | $105,000 | Implemented |
AS0394 # 05 Y:2005 | 05 | 2005 | INSTALL AUTOMATIC PACKING EQUIPMENT | $443,040 | $453,047 | Implemented |
IC0076 # 02 Y:2004 | 02 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $13,524 | $49,376 | Implemented |
IC0076 # 04 Y:2004 | 04 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $2,133 | $2,700 | Implemented |
IC0076 # 05 Y:2004 | 05 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $346 | $736 | Implemented |
IC0076 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,259 | $13,444 | Implemented |