Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
94
matching recommendationsNAICS | 3116 | Animal Slaughtering and Processing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0763 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,945 | $57,910 | Not Implemented |
UD0763 # 02 Y:2007 | 02 | 2007 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $30,994 | $8,900 | Implemented |
UD0763 # 01 Y:2007 | 01 | 2007 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $36,135 | $5,242 | Implemented |
NC0362 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,160 | $50 | Not Implemented |
NC0362 # 06 Y:2007 | 06 | 2007 | MAKE A NEW BY-PRODUCT | $655,523 | $2,000,000 | Not Implemented |
NC0362 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $295 | $537 | Not Implemented |
NC0362 # 03 Y:2007 | 03 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $3,512 | $3,546 | Not Implemented |
NC0362 # 02 Y:2007 | 02 | 2007 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $75,775 | $79,525 | Not Implemented |
NC0362 # 01 Y:2007 | 01 | 2007 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $43,646 | $70,525 | Not Implemented |
IC0127 # 02 Y:2007 | 02 | 2007 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $800 | $440 | Implemented |
IC0127 # 09 Y:2007 | 09 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,282 | $0 | Implemented |
IC0127 # 08 Y:2007 | 08 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $2,137 | $1,000 | Implemented |
IC0127 # 01 Y:2007 | 01 | 2007 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $14,659 | $0 | Implemented |
IC0127 # 03 Y:2007 | 03 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,063 | $51,889 | Implemented |
IC0127 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $120 | $1,026 | Implemented |
IC0127 # 05 Y:2007 | 05 | 2007 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $36,459 | $0 | Implemented |
IC0127 # 06 Y:2007 | 06 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,336 | $20,976 | Implemented |
IC0127 # 07 Y:2007 | 07 | 2007 | INSULATE BARE EQUIPMENT | $3,818 | $886 | Implemented |
IC0127 # 10 Y:2007 | 10 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $22,675 | $50,711 | Implemented |
WV0353 # 05 Y:2007 | 05 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,839 | $2,960 | Not Implemented |
WV0353 # 10 Y:2007 | 10 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,101 | $3,500 | Implemented |
WV0353 # 11 Y:2007 | 11 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $1,883 | $400 | Implemented |
WV0353 # 01 Y:2007 | 01 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $187,287 | $59,000 | Not Implemented |
WV0353 # 02 Y:2007 | 02 | 2007 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $133,786 | $400,000 | Not Implemented |
WV0353 # 03 Y:2007 | 03 | 2007 | REPAIR OR REPLACE STEAM TRAPS | $48,101 | $4,000 | Implemented |