Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,427
matching recommendationsNAICS | 31161 | Animal Slaughtering and Processing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BS0111 # 02 Y:2018 | 02 | 2018 | ISOLATE STEAM LINES TO AVOID HEATING AIR CONDITIONED AREAS | $768 | $1,485 | Implemented |
BS0111 # 03 Y:2018 | 03 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,707 | $2,970 | Implemented |
BS0111 # 04 Y:2018 | 04 | 2018 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $10,878 | $1,225 | Implemented |
BS0111 # 05 Y:2018 | 05 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,250 | $60 | Implemented |
BS0111 # 06 Y:2018 | 06 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,713 | $20 | Implemented |
BS0111 # 07 Y:2018 | 07 | 2018 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $130,754 | $100,744 | Not Implemented |
LS1809 # 01 Y:2018 | 01 | 2018 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,090 | $100 | Not Implemented |
LS1809 # 02 Y:2018 | 02 | 2018 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $134 | $45 | Not Implemented |
LS1809 # 03 Y:2018 | 03 | 2018 | INSTALL OCCUPANCY SENSORS | $401 | $300 | Not Implemented |
LS1809 # 04 Y:2018 | 04 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,902 | $4,019 | Not Implemented |
LS1809 # 05 Y:2018 | 05 | 2018 | INSULATE BARE EQUIPMENT | $364 | $440 | Not Implemented |
LS1809 # 06 Y:2018 | 06 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $33 | $50 | Not Implemented |
LS1809 # 07 Y:2018 | 07 | 2018 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $6,145 | $11,000 | Not Implemented |
UA0195 # 01 Y:2018 | 01 | 2018 | RECOVER WASTE HEAT FROM EQUIPMENT | $186,843 | $100,000 | Not Implemented |
UA0195 # 02 Y:2018 | 02 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,429 | $11,536 | Implemented |
UA0195 # 03 Y:2018 | 03 | 2018 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $18,189 | $19,100 | Not Implemented |
UA0195 # 04 Y:2018 | 04 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,476 | $500 | Implemented |
UA0195 # 05 Y:2018 | 05 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,589 | $2,465 | Implemented |
UA0195 # 06 Y:2018 | 06 | 2018 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $15,967 | $70,000 | Not Implemented |
AM0749 # 01 Y:2018 | 01 | 2018 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $136,440 | $167,100 | Not Implemented |
AM0749 # 02 Y:2018 | 02 | 2018 | COMBINE UTILITY METERS | $65,915 | $10,000 | Not Implemented |
AM0749 # 03 Y:2018 | 03 | 2018 | OPTIMIZE PLANT POWER FACTOR | $31,797 | $45,252 | Not Implemented |
AM0749 # 04 Y:2018 | 04 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,000 | $15,400 | Not Implemented |
AM0749 # 05 Y:2018 | 05 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,165 | $40 | Not Implemented |
AM0749 # 06 Y:2018 | 06 | 2018 | INSTALL OCCUPANCY SENSORS | $9,336 | $1,560 | Not Implemented |