Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,542
matching recommendationsNAICS | 3118 | Bakeries and Tortilla Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0465 # 01 Y:2013 | 01 | 2013 | REPLACE ELECTRIC MOTOR WITH FOSSIL FUEL ENGINE | $18,166 | $60,710 | Not Implemented |
SD0465 # 02 Y:2013 | 02 | 2013 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $16,606 | $29,550 | Not Implemented |
SD0465 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,054 | $2,000 | Implemented |
SD0465 # 04 Y:2013 | 04 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,677 | $200 | Implemented |
SD0465 # 05 Y:2013 | 05 | 2013 | INSTALL OCCUPANCY SENSORS | $1,318 | $1,521 | Not Implemented |
SD0465 # 06 Y:2013 | 06 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,113 | $200 | Not Implemented |
SD0465 # 07 Y:2013 | 07 | 2013 | USE PHOTOCELL CONTROLS | $402 | $1,100 | Not Implemented |
SF0412 # 01 Y:2012 | 01 | 2012 | REPAIR AND ELIMINATE STEAM LEAKS | $315 | $0 | Not Implemented |
SF0412 # 02 Y:2012 | 02 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,954 | $0 | Not Implemented |
SF0412 # 03 Y:2012 | 03 | 2012 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,535 | $314 | Not Implemented |
SF0412 # 04 Y:2012 | 04 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $806 | $275 | Not Implemented |
SF0412 # 05 Y:2012 | 05 | 2012 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $3,374 | $8,843 | Not Implemented |
SF0412 # 06 Y:2012 | 06 | 2012 | INSULATE BARE EQUIPMENT | $798 | $2,121 | Not Implemented |
SF0412 # 07 Y:2012 | 07 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,656 | $19,110 | Not Implemented |
LL0359 # 01 Y:2011 | 01 | 2011 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $24,918 | $64,500 | Not Implemented |
LL0359 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,575 | $400 | Implemented |
LL0359 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $639 | $3,115 | Implemented |
LL0359 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $602 | $385 | Implemented |
LL0359 # 05 Y:2011 | 05 | 2011 | INSULATE BARE EQUIPMENT | $515 | $394 | Not Implemented |
LL0359 # 06 Y:2011 | 06 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $514 | $623 | Not Implemented |
LL0359 # 07 Y:2011 | 07 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $421 | $220 | Not Implemented |
LL0359 # 08 Y:2011 | 08 | 2011 | INSTALL OCCUPANCY SENSORS | $59 | $240 | Implemented |
BD0396 # 01 Y:2011 | 01 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $72,574 | $19,000 | Not Implemented |
BD0396 # 02 Y:2011 | 02 | 2011 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $26,133 | $39,000 | Not Implemented |
BD0396 # 03 Y:2011 | 03 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,092 | $30,000 | Not Implemented |