Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
38
matching recommendationsNAICS | 311812 | Commercial Bakeries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CC0012 # 07 Y:2022 | 07 | 2022 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $47,241 | $125,000 | n/a |
CC0012 # 06 Y:2022 | 06 | 2022 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $7,230 | $30,000 | n/a |
CC0012 # 05 Y:2022 | 05 | 2022 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $3,233 | $0 | n/a |
CC0012 # 04 Y:2022 | 04 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,343 | $16,000 | n/a |
CC0012 # 03 Y:2022 | 03 | 2022 | OPERATE BOILERS ON HIGH FIRE SETTING | $4,544 | $10,000 | n/a |
CC0012 # 01 Y:2022 | 01 | 2022 | UPGRADE CONTROLS ON COMPRESSORS | $38,944 | $0 | n/a |
CC0012 # 02 Y:2022 | 02 | 2022 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $18,525 | $10,000 | n/a |
CC0006 # 01 Y:2022 | 01 | 2022 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $12,027 | $5,000 | n/a |
CC0006 # 02 Y:2022 | 02 | 2022 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $18,077 | $60,000 | n/a |
CC0006 # 03 Y:2022 | 03 | 2022 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $51,588 | $175,000 | n/a |
CC0006 # 04 Y:2022 | 04 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,854 | $13,360 | n/a |
CC0006 # 05 Y:2022 | 05 | 2022 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $20,461 | $10,000 | n/a |
CC0005 # 02 Y:2022 | 02 | 2022 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,273 | $1,000 | n/a |
CC0005 # 01 Y:2022 | 01 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,985 | $26,500 | n/a |
CC0005 # 07 Y:2022 | 07 | 2022 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $36,944 | $110,000 | n/a |
CC0005 # 06 Y:2022 | 06 | 2022 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $10,225 | $30,000 | n/a |
CC0005 # 05 Y:2022 | 05 | 2022 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $4,973 | $1,500 | n/a |
CC0005 # 04 Y:2022 | 04 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,997 | $6,000 | n/a |
CC0005 # 03 Y:2022 | 03 | 2022 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,217 | $0 | n/a |
NC0549 # 19 Y:2015 | 19 | 2015 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $437 | $510 | Not Implemented |
NC0549 # 18 Y:2015 | 18 | 2015 | DEVELOP A REPAIR/REPLACE POLICY | $1,939 | $4,256 | Not Implemented |
NC0549 # 17 Y:2015 | 17 | 2015 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $564 | $200 | Not Implemented |
NC0549 # 16 Y:2015 | 16 | 2015 | INSTALL OCCUPANCY SENSORS | $401 | $347 | Not Implemented |
NC0549 # 15 Y:2015 | 15 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,730 | $406 | Not Implemented |
NC0549 # 14 Y:2015 | 14 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $488 | $2,800 | Not Implemented |