IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

797

matching recommendations
Reset
NAICS 312111 Soft Drink Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0388 # 01 Y:2006 01 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,746 $4,846 Not Implemented
UF0388 # 02 Y:2006 02 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,378 $1,688 Not Implemented
UF0388 # 03 Y:2006 03 2006 INSTALL OCCUPANCY SENSORS $341 $342 Not Implemented
UF0388 # 04 Y:2006 04 2006 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $922 $2,346 Not Implemented
UF0388 # 05 Y:2006 05 2006 INSTALL / REPAIR INSULATION ON STEAM LINES $7,286 $1,238 Not Implemented
UF0388 # 06 Y:2006 06 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,957 $0 Not Implemented
UF0388 # 07 Y:2006 07 2006 INSTALL / REPAIR INSULATION ON STEAM LINES $193 $374 Not Implemented
UF0388 # 08 Y:2006 08 2006 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $1,088 $93 Not Implemented
UF0388 # 09 Y:2006 09 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,663 $1,320 Not Implemented
UF0388 # 10 Y:2006 10 2006 USE PHOTOCELL CONTROLS $553 $240 Not Implemented
UF0388 # 11 Y:2006 11 2006 PREHEAT COMBUSTION AIR WITH WASTE HEAT $12,667 $65,000 Not Implemented
CO0579 # 01 Y:2005 01 2005 TREAT AND REUSE RINSE WATERS $5,020 $8,800 Not Implemented
CO0579 # 02 Y:2005 02 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,640 $300 Implemented
CO0579 # 03 Y:2005 03 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $526 $718 Implemented
CO0579 # 04 Y:2005 04 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,970 $400 Implemented
CO0579 # 05 Y:2005 05 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,140 $3,200 Not Implemented
CO0579 # 06 Y:2005 06 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $570 $230 Not Implemented
CO0579 # 07 Y:2005 07 2005 UPGRADE CONTROLS ON COMPRESSORS $280 $380 Implemented
CO0579 # 08 Y:2005 08 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,010 $11,780 Not Implemented
CO0579 # 09 Y:2005 09 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,840 $11,540 Not Implemented
CO0579 # 10 Y:2005 10 2005 USE SOLAR HEAT TO HEAT WATER $1,380 $5,220 Implemented
CO0579 # 11 Y:2005 11 2005 USE SOLAR HEAT TO HEAT MAKE-UP AIR $100 $850 Not Implemented
AS0403 # 01 Y:2005 01 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $17,641 $1,000 Not Implemented
AS0403 # 02 Y:2005 02 2005 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $16,622 $10,000 Not Implemented
AS0403 # 03 Y:2005 03 2005 DIRECT WARMEST AIR TO COMBUSTION INTAKE $15,050 $2,000 Not Implemented