IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

38

matching recommendations
Reset
NAICS 31212 Breweries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
DL0137 # 01 Y:2014 01 2014 INCREASE AMOUNT OF CONDENSATE RETURNED $17,190 $20,000 Implemented
DL0137 # 02 Y:2014 02 2014 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $14,240 $5,460 Not Implemented
DL0137 # 03 Y:2014 03 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $5,900 $38,400 Not Implemented
DL0137 # 04 Y:2014 04 2014 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $890 $2,220 Not Implemented
DL0137 # 05 Y:2014 05 2014 RECOVER WASTE HEAT FROM EQUIPMENT $1,520 $8,430 Not Implemented
DL0137 # 06 Y:2014 06 2014 INSULATE BARE EQUIPMENT $745 $160 Not Implemented
DL0137 # 07 Y:2014 07 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $2,350 $6,300 Implemented
DL0137 # 08 Y:2014 08 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $970 $1,200 Implemented
DL0137 # 09 Y:2014 09 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $245 $2,280 Not Implemented
DL0137 # 10 Y:2014 10 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,820 $10,075 Not Implemented
DL0137 # 11 Y:2014 11 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $640 $1,040 Not Implemented
OR0636 # 02 Y:2014 02 2014 UPGRADE OBSOLETE EQUIPMENT $55,473 $50,000 Not Implemented
OR0636 # 01 Y:2014 01 2014 IMPROVE COMBUSTION CONTROL CAPABILITY $31,057 $7,123 Not Implemented
OR0636 # 03 Y:2014 03 2014 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $5,708 $7,000 Implemented
OR0636 # 04 Y:2014 04 2014 REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE $27,166 $37,500 Not Implemented
OR0636 # 05 Y:2014 05 2014 MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT $712,265 $3,300,000 Not Implemented
CO0688 # 05 Y:2014 05 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,160 $3,140 Not Implemented
CO0688 # 04 Y:2014 04 2014 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $610 $2,270 Not Implemented
CO0688 # 03 Y:2014 03 2014 RECOVER WASTE HEAT FROM EQUIPMENT $2,490 $10,380 Not Implemented
CO0688 # 02 Y:2014 02 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,390 $1,500 Implemented
CO0688 # 01 Y:2014 01 2014 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $4,830 $8,050 Not Implemented
SD0481 # 02 Y:2014 02 2014 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $36,872 $91,000 Implemented
SD0481 # 04 Y:2014 04 2014 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $22,759 $25,200 Not Implemented
SD0481 # 03 Y:2014 03 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $31,839 $1,000 Implemented
SD0481 # 01 Y:2014 01 2014 USE COLD WASTE WATER TO COOL CHILLER FEED WATER $134,111 $80,720 Implemented