Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

958

matching recommendations
Reset
NAICS 313 Textile Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0293 # 04 Y:2005 04 2005 INSTALL OCCUPANCY SENSORS $1,306 $1,125 Implemented
BD0293 # 05 Y:2005 05 2005 USE POWER DURING OFF-PEAK PERIODS $950 $1,700 Implemented
BD0293 # 06 Y:2005 06 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $740 $700 Implemented
BD0293 # 07 Y:2005 07 2005 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $4,251 $1,250 Implemented
BD0293 # 08 Y:2005 08 2005 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $1,306 $3,500 Not Implemented
OR0487 # 01 Y:2005 01 2005 MINIMIZE WATER USAGE $215,000 $620,000 Not Implemented
OR0487 # 02 Y:2005 02 2005 MINIMIZE WATER USAGE $51,000 $107,000 Not Implemented
OR0487 # 03 Y:2005 03 2005 USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) $39,000 $16,400 Not Implemented
OR0487 # 04 Y:2005 04 2005 INSTALL / REPAIR INSULATION ON STEAM LINES $17,600 $23,000 Not Implemented
OR0487 # 05 Y:2005 05 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,630 $0 Implemented
OR0487 # 06 Y:2005 06 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,637 $3,150 Implemented
OR0487 # 07 Y:2005 07 2005 INSTALL OCCUPANCY SENSORS $2,100 $104 Implemented
OR0487 # 08 Y:2005 08 2005 UPGRADE CONTROLS ON COMPRESSORS $1,500 $600 Not Implemented
NC0319 # 01 Y:2005 01 2005 ADJUST BURNERS FOR EFFICIENT OPERATION $1,809 $2,000 Implemented
NC0319 # 02 Y:2005 02 2005 RECOVER WASTE HEAT FROM EQUIPMENT $19,522 $27,100 Not Implemented
NC0319 # 03 Y:2005 03 2005 DEVELOP A REPAIR/REPLACE POLICY $4,681 $1,000 Implemented
NC0319 # 04 Y:2005 04 2005 TURN OFF EQUIPMENT WHEN NOT IN USE $6,753 $0 Implemented
NC0319 # 05 Y:2005 05 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,156 $1,000 Implemented
NC0319 # 06 Y:2005 06 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $18,604 $0 Implemented
NC0319 # 07 Y:2005 07 2005 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $2,151 $2,000 Implemented
NC0319 # 08 Y:2005 08 2005 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $1,126 $0 Implemented
NC0319 # 09 Y:2005 09 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,138 $417 Not Implemented
NC0319 # 10 Y:2005 10 2005 INSTALL / REPAIR INSULATION ON STEAM LINES $933 $300 Implemented
NC0319 # 11 Y:2005 11 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $823 $100 Implemented
SU0210 # 01 Y:2005 01 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,587 $0 Implemented