Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
223
matching recommendationsNAICS | 31321 | Broadwoven Fabric Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0487 # 02 Y:2005 | 02 | 2005 | MINIMIZE WATER USAGE | $51,000 | $107,000 | Not Implemented |
OR0487 # 03 Y:2005 | 03 | 2005 | USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) | $39,000 | $16,400 | Not Implemented |
OR0487 # 04 Y:2005 | 04 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $17,600 | $23,000 | Not Implemented |
OR0487 # 05 Y:2005 | 05 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,630 | $0 | Implemented |
OR0487 # 06 Y:2005 | 06 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,637 | $3,150 | Implemented |
OR0487 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $2,100 | $104 | Implemented |
OR0487 # 08 Y:2005 | 08 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $1,500 | $600 | Not Implemented |
SU0210 # 01 Y:2005 | 01 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,587 | $0 | Implemented |
SU0210 # 02 Y:2005 | 02 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,063 | $0 | Not Implemented |
SU0210 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $328 | $143 | Implemented |
SU0210 # 04 Y:2005 | 04 | 2005 | USE SYNTHETIC LUBRICANT | $1,943 | $1,000 | Implemented |
SU0210 # 05 Y:2005 | 05 | 2005 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $28,070 | $35,100 | Implemented |
SU0210 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,715 | $11,225 | Not Implemented |
MA0577 # 01 Y:2005 | 01 | 2005 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $75,813 | $205,500 | Implemented |
MA0577 # 02 Y:2005 | 02 | 2005 | IMPROVE COMBUSTION CONTROL CAPABILITY | $52,930 | $50,000 | Implemented |
MA0577 # 03 Y:2005 | 03 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $46,138 | $58,000 | Implemented |
MA0577 # 04 Y:2005 | 04 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $28,600 | $980 | Implemented |
MA0577 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,371 | $300 | Implemented |
MA0577 # 06 Y:2005 | 06 | 2005 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $6,784 | $40,425 | Implemented |
NC0304 # 01 Y:2004 | 01 | 2004 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $25,824 | $24,000 | n/a |
NC0304 # 02 Y:2004 | 02 | 2004 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $27,494 | $13,050 | Implemented |
NC0304 # 03 Y:2004 | 03 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $20,008 | $3,000 | Implemented |
NC0304 # 04 Y:2004 | 04 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,821 | $400 | Implemented |
NC0304 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,732 | $100 | Implemented |
NC0304 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,024 | $4,207 | Not Implemented |