Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
654
matching recommendationsNAICS | 3212 | Veneer, Plywood, and Engineered Wood Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0537 # 08 Y:2008 | 08 | 2008 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $179,500 | $279,600 | Not Implemented |
OR0530 # 01 Y:2008 | 01 | 2008 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $84,400 | $21,000 | Not Implemented |
OR0530 # 02 Y:2008 | 02 | 2008 | Maintenance | $70,600 | $500 | Implemented |
OR0530 # 03 Y:2008 | 03 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $31,500 | $24,110 | Not Implemented |
OR0530 # 04 Y:2008 | 04 | 2008 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $13,800 | $11,475 | Not Implemented |
OR0530 # 05 Y:2008 | 05 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,580 | $4,200 | Not Implemented |
OR0530 # 06 Y:2008 | 06 | 2008 | General | $4,900 | $500 | Implemented |
OR0530 # 07 Y:2008 | 07 | 2008 | OPTIMIZE PLANT POWER FACTOR | $27,360 | $114,000 | Not Implemented |
BD0337 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $927 | $1,115 | Not Implemented |
BD0337 # 02 Y:2007 | 02 | 2007 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $14,425 | $480 | Implemented |
BD0337 # 03 Y:2007 | 03 | 2007 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $2,084 | $2,150 | Not Implemented |
BD0337 # 04 Y:2007 | 04 | 2007 | USE SYNTHETIC LUBRICANT | $228 | $601 | Not Implemented |
BD0337 # 05 Y:2007 | 05 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $926 | $2 | Not Implemented |
OR0521 # 01 Y:2007 | 01 | 2007 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $92,300 | $44,300 | Implemented |
OR0521 # 02 Y:2007 | 02 | 2007 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $37,000 | $20,600 | Implemented |
OR0521 # 03 Y:2007 | 03 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $27,300 | $0 | Implemented |
OR0521 # 04 Y:2007 | 04 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $27,800 | $12,500 | Implemented |
OR0521 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,600 | $9,600 | Implemented |
OR0521 # 06 Y:2007 | 06 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,300 | $0 | Implemented |
OR0521 # 07 Y:2007 | 07 | 2007 | UPGRADE CONTROLS ON COMPRESSORS | $7,100 | $45,000 | Implemented |
OR0521 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,250 | $9,300 | Implemented |
OR0521 # 09 Y:2007 | 09 | 2007 | INSTALL OCCUPANCY SENSORS | $3,720 | $5,100 | Implemented |
OR0521 # 10 Y:2007 | 10 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,600 | $4,500 | Implemented |
OR0521 # 11 Y:2007 | 11 | 2007 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,900 | $1,800 | Implemented |
OR0519 # 01 Y:2007 | 01 | 2007 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $5,658,000 | $660,000 | Not Implemented |