Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
198
matching recommendationsNAICS | 321219 | Reconstituted Wood Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0657 # 02 Y:2015 | 02 | 2015 | INSULATE BARE EQUIPMENT | $24,174 | $32,596 | Not Implemented |
OR0657 # 03 Y:2015 | 03 | 2015 | ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION | $207,496 | $694,826 | Not Implemented |
OR0622 # 01 Y:2013 | 01 | 2013 | IMPROVE COMBUSTION CONTROL CAPABILITY | $9,626 | $1,814 | Not Implemented |
OR0622 # 02 Y:2013 | 02 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $10,631 | $10,763 | Not Implemented |
OR0622 # 03 Y:2013 | 03 | 2013 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $8,423 | $20,917 | Not Implemented |
OR0622 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,279 | $15,410 | Not Implemented |
NC0427 # 01 Y:2011 | 01 | 2011 | BURN A LESS EXPENSIVE GRADE OF FUEL | $155,882 | $10,000 | Implemented |
NC0427 # 02 Y:2011 | 02 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $209,278 | $1,200 | Not Implemented |
NC0427 # 03 Y:2011 | 03 | 2011 | KEEP BOILER TUBES CLEAN | $164,666 | $20,000 | Implemented |
NC0427 # 04 Y:2011 | 04 | 2011 | KEEP BOILER TUBES CLEAN | $104,205 | $18,000 | Implemented |
NC0427 # 05 Y:2011 | 05 | 2011 | LOWER OPERATING PRESSURE OF CONDENSER (STEAM) | $178,345 | $50,000 | Implemented |
NC0427 # 06 Y:2011 | 06 | 2011 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $10,000 | $200 | Implemented |
NC0427 # 07 Y:2011 | 07 | 2011 | INSULATE FEEDWATER TANK | $3,200 | $1,200 | Implemented |
NC0427 # 08 Y:2011 | 08 | 2011 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $3,000 | $600 | Implemented |
NC0427 # 09 Y:2011 | 09 | 2011 | REPAIR AND ELIMINATE STEAM LEAKS | $106,205 | $1,200 | Implemented |
NC0427 # 10 Y:2011 | 10 | 2011 | REPAIR OR REPLACE STEAM TRAPS | $5,500 | $150 | Not Implemented |
NC0427 # 11 Y:2011 | 11 | 2011 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,500 | $1,050 | Not Implemented |
NC0427 # 12 Y:2011 | 12 | 2011 | INCREASE AMOUNT OF CONDENSATE RETURNED | $126,880 | $500,000 | Not Implemented |
NC0416 # 01 Y:2010 | 01 | 2010 | KEEP BOILER TUBES CLEAN | $359,066 | $411,700 | Not Implemented |
NC0416 # 02 Y:2010 | 02 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $14,117 | $50 | Implemented |
NC0416 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,948 | $100 | Implemented |
NC0416 # 04 Y:2010 | 04 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,462 | $6,800 | Not Implemented |
NC0416 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,679 | $30,438 | Not Implemented |
NC0416 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $284 | $568 | Implemented |
NC0416 # 07 Y:2010 | 07 | 2010 | INSTALL OCCUPANCY SENSORS | $415 | $949 | Implemented |