Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
971
matching recommendationsNAICS | 32191 | Millwork |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0106 # 07 Y:2005 | 07 | 2005 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $756 | $1,536 | Not Implemented |
IA0363 # 01 Y:2005 | 01 | 2005 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $5,128 | $1,344 | Not Implemented |
IA0363 # 02 Y:2005 | 02 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $20,682 | $12,835 | Not Implemented |
IA0363 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,962 | $1,023 | Implemented |
IA0363 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,383 | $15,627 | Implemented |
IA0363 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $971 | $2,171 | Not Implemented |
IA0363 # 06 Y:2005 | 06 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $20,328 | $0 | Implemented |
IA0363 # 07 Y:2005 | 07 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,742 | $95 | Not Implemented |
IA0363 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $859 | $1,617 | Not Implemented |
OR0476 # 01 Y:2005 | 01 | 2005 | INSTALL SENSORS TO DETECT DEFECTS | $59,097 | $38,400 | Not Implemented |
OR0476 # 02 Y:2005 | 02 | 2005 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $1,039,000 | $1,200,000 | Not Implemented |
OR0476 # 03 Y:2005 | 03 | 2005 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $9,028 | $600 | Implemented |
OR0476 # 04 Y:2005 | 04 | 2005 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $32,100 | $47,900 | Not Implemented |
WI0482 # 01 Y:2005 | 01 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $29,756 | $55,500 | Not Implemented |
WI0482 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,773 | $50,985 | Not Implemented |
WI0482 # 03 Y:2005 | 03 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $8,362 | $3,571 | Implemented |
WI0482 # 04 Y:2005 | 04 | 2005 | INSTALL AUTOMATIC BOILER FUEL FEED SYSTEM | $6,615 | $13,500 | Not Implemented |
WI0482 # 05 Y:2005 | 05 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,791 | $640 | Not Implemented |
WI0482 # 06 Y:2005 | 06 | 2005 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,495 | $500 | Implemented |
WI0482 # 07 Y:2005 | 07 | 2005 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $697 | $1,000 | Not Implemented |
WI0482 # 08 Y:2005 | 08 | 2005 | USE PHOTOCELL CONTROLS | $617 | $2,200 | Not Implemented |
MI0070 # 01 Y:2004 | 01 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $21,868 | $2,300 | Implemented |
MI0070 # 02 Y:2004 | 02 | 2004 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $197,433 | $74,805 | Implemented |
MI0070 # 03 Y:2004 | 03 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $175 | $0 | Not Implemented |
MI0070 # 04 Y:2004 | 04 | 2004 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $11,397 | $5,248 | Implemented |