Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
169
matching recommendationsNAICS | 321918 | Other Millwork (including Flooring) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0464 # 04 Y:2016 | 04 | 2016 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $736 | $150 | Implemented |
UM0464 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,786 | $3,794 | Implemented |
SU0405 # 09 Y:2016 | 09 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $168 | $336 | Implemented |
SU0405 # 10 Y:2016 | 10 | 2016 | ELIMINATE/REDUCE AN OPERATION | $607 | $1,364 | Implemented |
SU0405 # 08 Y:2016 | 08 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $297 | $476 | Implemented |
SU0405 # 06 Y:2016 | 06 | 2016 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $193 | $272 | Implemented |
SU0405 # 05 Y:2016 | 05 | 2016 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $337 | $83 | Implemented |
SU0405 # 02 Y:2016 | 02 | 2016 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $609 | $0 | Implemented |
SU0405 # 01 Y:2016 | 01 | 2016 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,861 | $0 | Implemented |
WV0513 # 11 Y:2015 | 11 | 2015 | INSTALL SET-BACK TIMERS | $731 | $1,164 | Implemented |
WV0513 # 10 Y:2015 | 10 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,405 | $1,113 | Implemented |
WV0513 # 09 Y:2015 | 09 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,786 | $903 | Implemented |
WV0513 # 08 Y:2015 | 08 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,613 | $0 | Implemented |
WV0513 # 07 Y:2015 | 07 | 2015 | DEVELOP A REPAIR/REPLACE POLICY | $4,518 | $879 | Implemented |
WV0513 # 05 Y:2015 | 05 | 2015 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $18,366 | $1,000 | Implemented |
WV0513 # 03 Y:2015 | 03 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $44,726 | $1,700 | Implemented |
WV0513 # 02 Y:2015 | 02 | 2015 | INSULATE BARE EQUIPMENT | $45,398 | $21,389 | Implemented |
NC0545 # 18 Y:2015 | 18 | 2015 | DEVELOP A REPAIR/REPLACE POLICY | $1,205 | $4,256 | Implemented |
NC0545 # 12 Y:2015 | 12 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $189 | $48 | Implemented |
NC0545 # 10 Y:2015 | 10 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $468 | $278 | Implemented |
NC0545 # 09 Y:2015 | 09 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,889 | $30,733 | Implemented |
NC0545 # 02 Y:2015 | 02 | 2015 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $4,151 | $2,000 | Implemented |
NC0545 # 01 Y:2015 | 01 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $32,534 | $30,000 | Implemented |
NC0545 # 06 Y:2015 | 06 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,106 | $100 | Implemented |
UD0915 # 03 Y:2014 | 03 | 2014 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $7,714 | $1,800 | Implemented |