Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
188
matching recommendationsNAICS | 322130 | Paperboard Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0080 # 01 Y:2012 | 01 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,088 | $100 | Implemented |
DL0080 # 02 Y:2012 | 02 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $15,456 | $26,650 | Implemented |
DL0080 # 03 Y:2012 | 03 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $14,835 | $380 | Not Implemented |
DL0080 # 04 Y:2012 | 04 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,451 | $2,160 | Implemented |
DL0080 # 05 Y:2012 | 05 | 2012 | USE WATER-BASED ADHESIVES | $7,845 | $145 | Implemented |
DL0080 # 06 Y:2012 | 06 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,140 | $10,000 | Implemented |
DL0080 # 07 Y:2012 | 07 | 2012 | INSTALL TIMERS AND/OR THERMOSTATS | $8,500 | $112 | Not Implemented |
DL0080 # 08 Y:2012 | 08 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,400 | $287 | Not Implemented |
DL0080 # 09 Y:2012 | 09 | 2012 | INSTALL OCCUPANCY SENSORS | $6,200 | $121 | Not Implemented |
DL0078 # 01 Y:2011 | 01 | 2011 | REPLACE BOILER | $123,207 | $900,000 | Not Implemented |
DL0078 # 02 Y:2011 | 02 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $191,452 | $500,000 | Not Implemented |
DL0078 # 03 Y:2011 | 03 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $30,553 | $42,800 | Not Implemented |
DL0078 # 04 Y:2011 | 04 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $57,285 | $28,500 | Not Implemented |
DL0078 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $33,872 | $165,720 | Not Implemented |
DL0078 # 06 Y:2011 | 06 | 2011 | INSTALL SPECTRAL REFLECTORS / DELAMP | $14,637 | $800 | Not Implemented |
DL0078 # 07 Y:2011 | 07 | 2011 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $77,835 | $42,650 | Implemented |
DL0078 # 08 Y:2011 | 08 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $23,761 | $22,500 | Not Implemented |
WV0401 # 01 Y:2010 | 01 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $61,713 | $37,440 | Not Implemented |
WV0401 # 02 Y:2010 | 02 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $57,379 | $6,240 | Implemented |
WV0401 # 03 Y:2010 | 03 | 2010 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $38,419 | $128,000 | Implemented |
WV0401 # 04 Y:2010 | 04 | 2010 | DEVELOP A REPAIR/REPLACE POLICY | $19,593 | $1,638 | Not Implemented |
WV0401 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,792 | $7,958 | Implemented |
WV0401 # 06 Y:2010 | 06 | 2010 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $11,226 | $20,400 | Implemented |
WV0401 # 07 Y:2010 | 07 | 2010 | INSTALL DRY SPRINKLER SYSTEM OR OTHER METHOD TO REDUCE HEATING REQUIREMENTS | $7,432 | $16,240 | Not Implemented |
WV0401 # 08 Y:2010 | 08 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $6,432 | $2,028 | Implemented |