Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,224

matching recommendations
Reset
NAICS 3222 Converted Paper Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0222 # 01 Y:2003 01 2003 PREHEAT COMBUSTION AIR WITH WASTE HEAT $11,730 $8,788 Not Implemented
MS0222 # 02 Y:2003 02 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,928 $196 Implemented
MS0222 # 03 Y:2003 03 2003 REPAIR AND ELIMINATE STEAM LEAKS $2,178 $90 Implemented
MS0222 # 04 Y:2003 04 2003 USE RADIANT HEATER FOR SPOT HEATING $2,158 $1,649 Not Implemented
MS0222 # 05 Y:2003 05 2003 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,994 $0 Not Implemented
MS0222 # 06 Y:2003 06 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $1,717 $1,717 Not Implemented
MS0222 # 07 Y:2003 07 2003 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $1,680 $400 Not Implemented
UF0317 # 01 Y:2003 01 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,161 $11,978 n/a
UF0317 # 02 Y:2003 02 2003 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $4,254 $1,640 n/a
UF0317 # 03 Y:2003 03 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,925 $5,839 n/a
UF0317 # 04 Y:2003 04 2003 OPTIMIZE PLANT POWER FACTOR $5,621 $15,000 n/a
UF0317 # 05 Y:2003 05 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,795 $7,524 n/a
UF0317 # 06 Y:2003 06 2003 REPAIR AND ELIMINATE STEAM LEAKS $25,640 $120 n/a
UF0317 # 07 Y:2003 07 2003 $6,065 $10,440 n/a
UF0317 # 08 Y:2003 08 2003 $48,077 $145,000 n/a
IC0055 # 01 Y:2003 01 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $845 $2,361 Not Implemented
IC0055 # 02 Y:2003 02 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,371 $2,900 Implemented
IC0055 # 03 Y:2003 03 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $571 $863 Implemented
IC0055 # 04 Y:2003 04 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $720 $1,265 Not Implemented
IC0055 # 05 Y:2003 05 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $417 $454 Not Implemented
IC0055 # 06 Y:2003 06 2003 CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS $9,243 $61,200 Not Implemented
IC0055 # 07 Y:2003 07 2003 REPAIR AND ELIMINATE STEAM LEAKS $5,069 $2,100 Implemented
IC0055 # 08 Y:2003 08 2003 REDUCE SCRAP PRODUCTION $130 $0 Not Implemented
IC0055 # 09 Y:2003 09 2003 $36,930 $11,045 Not Implemented
IC0053 # 01 Y:2003 01 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,095 $5,808 Not Implemented