Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
300
matching recommendationsNAICS | 324122 | Asphalt Shingle and Coating Materials Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0468 # 06 Y:2011 | 06 | 2011 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $2,025 | $150 | Implemented |
IA0468 # 07 Y:2011 | 07 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,116 | $3,625 | Not Implemented |
IA0468 # 08 Y:2011 | 08 | 2011 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $21,972 | $10,000 | Not Implemented |
IA0468 # 09 Y:2011 | 09 | 2011 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $4,944 | $2,436 | Implemented |
IA0468 # 10 Y:2011 | 10 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,265 | $1,000 | Implemented |
CO0637 # 01 Y:2010 | 01 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $13,860 | $24,000 | Implemented |
CO0637 # 02 Y:2010 | 02 | 2010 | INSULATE BARE EQUIPMENT | $3,450 | $1,790 | Not Implemented |
CO0637 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,200 | $460 | Implemented |
CO0637 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,650 | $20,950 | Implemented |
CO0637 # 05 Y:2010 | 05 | 2010 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,560 | $20,500 | Not Implemented |
CO0637 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $430 | $450 | Not Implemented |
CO0637 # 07 Y:2010 | 07 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $220 | $900 | Not Implemented |
SF0387 # 01 Y:2010 | 01 | 2010 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $5,144 | $0 | Not Implemented |
SF0387 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $747 | $0 | Implemented |
SF0387 # 03 Y:2010 | 03 | 2010 | USE PHOTOCELL CONTROLS | $7,756 | $1,353 | Implemented |
SF0387 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,874 | $1,627 | Implemented |
SF0387 # 05 Y:2010 | 05 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,964 | $7,727 | Implemented |
SF0387 # 06 Y:2010 | 06 | 2010 | USE OPTIMUM THICKNESS INSULATION | $791 | $1,536 | Implemented |
SF0387 # 07 Y:2010 | 07 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $397 | $798 | Implemented |
SF0387 # 08 Y:2010 | 08 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,393 | $2,851 | Implemented |
SF0387 # 09 Y:2010 | 09 | 2010 | INSTALL OCCUPANCY SENSORS | $920 | $2,132 | Implemented |
SF0387 # 10 Y:2010 | 10 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,160 | $3,840 | Implemented |
SF0387 # 11 Y:2010 | 11 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,342 | $6,259 | Implemented |
AM0553 # 01 Y:2008 | 01 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $80,000 | $960 | Implemented |
AM0553 # 02 Y:2008 | 02 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $24,080 | $1,500 | Implemented |