Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,329
matching recommendationsNAICS | 325 | Chemical Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0347 # 04 Y:2012 | 04 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $653 | $2,000 | Implemented |
LE0347 # 05 Y:2012 | 05 | 2012 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $5,309 | $20,000 | Implemented |
LE0347 # 06 Y:2012 | 06 | 2012 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $10,156 | $16,300 | Implemented |
LE0347 # 08 Y:2012 | 08 | 2012 | REPAIR AND ELIMINATE STEAM LEAKS | $475 | $675 | Implemented |
NC0461 # 04 Y:2012 | 04 | 2012 | ADJUST BURNERS FOR EFFICIENT OPERATION | $24,541 | $2,400 | Implemented |
NC0461 # 05 Y:2012 | 05 | 2012 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $84,150 | $40,000 | Implemented |
NC0461 # 06 Y:2012 | 06 | 2012 | REDUCE EXCESSIVE BOILER BLOWDOWN | $4,695 | $0 | Implemented |
NC0461 # 08 Y:2012 | 08 | 2012 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $458,904 | $314,375 | Implemented |
NC0461 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,912 | $7,160 | Implemented |
SU0321 # 02 Y:2012 | 02 | 2012 | UPGRADE OBSOLETE EQUIPMENT | $206 | $669 | Implemented |
SU0321 # 03 Y:2012 | 03 | 2012 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $124 | $395 | Implemented |
SU0321 # 04 Y:2012 | 04 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $32,346 | $123,757 | Implemented |
SU0321 # 05 Y:2012 | 05 | 2012 | INSTALL OCCUPANCY SENSORS | $955 | $4,144 | Implemented |
SU0321 # 07 Y:2012 | 07 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,284 | $1,655 | Implemented |
SU0321 # 08 Y:2012 | 08 | 2012 | ELIMINATE/REDUCE AN OPERATION | $2,320 | $4,530 | Implemented |
DL0089 # 01 Y:2012 | 01 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $14,050 | $6,800 | Implemented |
DL0089 # 02 Y:2012 | 02 | 2012 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $7,675 | $27,000 | Implemented |
DL0089 # 03 Y:2012 | 03 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,880 | $0 | Implemented |
DL0089 # 04 Y:2012 | 04 | 2012 | REDUCE VENTILATION AIR | $620 | $81 | Implemented |
NC0456 # 02 Y:2012 | 02 | 2012 | REPAIR OR REPLACE STEAM TRAPS | $34,238 | $5,500 | Implemented |
NC0456 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $997 | $100 | Implemented |
TT0092 # 01 Y:2012 | 01 | 2012 | REPAIR OR REPLACE STEAM TRAPS | $18,416 | $2,040 | Implemented |
TT0092 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,171 | $3,000 | Implemented |
TT0092 # 08 Y:2012 | 08 | 2012 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $15,500 | $9,600 | Implemented |
WV0450 # 01 Y:2012 | 01 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $173,557 | $1,000 | Implemented |