Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

378

matching recommendations
Reset
NAICS 325 Chemical Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0243 # 04 Y:2006 04 2006 AIR CONDITION ONLY SPACE NECESSARY $27,306 $200 Not Implemented
LE0243 # 05 Y:2006 05 2006 LOWER CEILING TO REDUCE CONDITIONED SPACE $18,286 $50,000 Not Implemented
LE0243 # 06 Y:2006 06 2006 TURN OFF EQUIPMENT WHEN NOT IN USE $8,730 $2,400 Not Implemented
LE0243 # 07 Y:2006 07 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,824 $80 Not Implemented
LE0243 # 08 Y:2006 08 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,925 $2,000 Not Implemented
LE0243 # 09 Y:2006 09 2006 INSTALL OCCUPANCY SENSORS $995 $525 Not Implemented
LE0243 # 10 Y:2006 10 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,687 $7,500 Not Implemented
UM0306 # 01 Y:2006 01 2006 RECOVER WASTE HEAT FROM EQUIPMENT $12,385 $2,500 Implemented
UM0306 # 02 Y:2006 02 2006 RECOVER WASTE HEAT FROM EQUIPMENT $11,812 $22,458 Not Implemented
UM0306 # 03 Y:2006 03 2006 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,934 $2,500 Not Implemented
UM0306 # 04 Y:2006 04 2006 ELIMINATE COOLING OF PROCESS STREAMS WHICH SUBSEQUENTLY MUST BE HEATED AND VICE VERSA $8,336 $7,520 Implemented
UM0306 # 05 Y:2006 05 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,571 $9,421 Implemented
UM0306 # 06 Y:2006 06 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,482 $2,429 Not Implemented
UM0306 # 07 Y:2006 07 2006 INSTALL / REPAIR INSULATION ON STEAM LINES $1,558 $197 Implemented
WV0346 # 09 Y:2006 09 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $534 $131 Not Implemented
WV0346 # 08 Y:2006 08 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $800 $14 Implemented
WV0346 # 01 Y:2006 01 2006 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $12,230 $1,143 Implemented
WV0346 # 02 Y:2006 02 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,998 $13,688 Implemented
WV0346 # 03 Y:2006 03 2006 USE RADIANT HEATER FOR SPOT HEATING $4,996 $8,800 Not Implemented
WV0346 # 04 Y:2006 04 2006 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,442 $4,540 Not Implemented
WV0346 # 05 Y:2006 05 2006 RECOVER WASTE HEAT FROM EQUIPMENT $1,952 $656 Not Implemented
WV0346 # 06 Y:2006 06 2006 INSULATE BARE EQUIPMENT $1,502 $737 Implemented
WV0346 # 07 Y:2006 07 2006 DEVELOP A REPAIR/REPLACE POLICY $850 $230 Implemented
LE0239 # 01 Y:2006 01 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $392,390 $95,000 Not Implemented
LE0239 # 02 Y:2006 02 2006 REPAIR AND ELIMINATE STEAM LEAKS $280,038 $31,000 Not Implemented