Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
27
matching recommendationsNAICS | 32552 | Adhesive Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0748 # 06 Y:2018 | 06 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,020 | $345 | Implemented |
AM0748 # 05 Y:2018 | 05 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,640 | $0 | Implemented |
AM0748 # 04 Y:2018 | 04 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,425 | $1,000 | Implemented |
AM0748 # 03 Y:2018 | 03 | 2018 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $13,900 | $18,200 | Implemented |
AM0748 # 02 Y:2018 | 02 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,300 | $51,700 | Implemented |
AM0748 # 07 Y:2018 | 07 | 2018 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,160 | $145 | Implemented |
AM0591 # 05 Y:2011 | 05 | 2011 | REPAIR OR REPLACE STEAM TRAPS | $5,270 | $1,300 | Implemented |
AM0591 # 12 Y:2011 | 12 | 2011 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $310 | $170 | Implemented |
AM0591 # 09 Y:2011 | 09 | 2011 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,800 | $325 | Implemented |
AM0591 # 07 Y:2011 | 07 | 2011 | INSULATE BARE EQUIPMENT | $2,200 | $950 | Implemented |
AM0591 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,275 | $4,290 | Implemented |
AM0591 # 04 Y:2011 | 04 | 2011 | REPAIR AND ELIMINATE STEAM LEAKS | $9,540 | $5,000 | Implemented |
AM0591 # 03 Y:2011 | 03 | 2011 | OPTIMIZE PLANT POWER FACTOR | $10,060 | $15,900 | Implemented |
TA0062 # 07 Y:2003 | 07 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $390 | $100 | Implemented |
TA0062 # 01 Y:2003 | 01 | 2003 | COMBINE UTILITY METERS | $44,572 | $57,200 | Implemented |
TA0062 # 02 Y:2003 | 02 | 2003 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $26,157 | $0 | Implemented |
TA0062 # 03 Y:2003 | 03 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $7,420 | $13,085 | Implemented |
TA0062 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,035 | $1,936 | Implemented |
TA0062 # 06 Y:2003 | 06 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $780 | $144 | Implemented |
TA0062 # 08 Y:2003 | 08 | 2003 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $140 | $0 | Implemented |
AM0432 # 09 Y:2003 | 09 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $220 | $50 | Implemented |
AM0432 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,380 | $500 | Implemented |
AM0432 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,680 | $4,300 | Implemented |
AM0432 # 03 Y:2003 | 03 | 2003 | REPAIR OR REPLACE STEAM TRAPS | $9,300 | $940 | Implemented |
AM0432 # 02 Y:2003 | 02 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $12,670 | $560 | Implemented |