Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
582
matching recommendationsNAICS | 3256 | Soap, Cleaning Compound, and Toilet Preparation Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0185 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $604 | $1,719 | n/a |
IC0185 # 04 Y:2011 | 04 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $283 | $1 | n/a |
IC0185 # 05 Y:2011 | 05 | 2011 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $1,057 | $115 | n/a |
IC0185 # 06 Y:2011 | 06 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $205 | $334 | n/a |
IC0185 # 07 Y:2011 | 07 | 2011 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $260,354 | $102,100 | n/a |
UD0832 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,751 | $40,000 | Implemented |
UD0832 # 02 Y:2011 | 02 | 2011 | DISCONNECT BALLASTS | $2,570 | $250 | Implemented |
UD0832 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $1,977 | $1,063 | Implemented |
UD0832 # 04 Y:2011 | 04 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $56,419 | $39,141 | Implemented |
UD0832 # 05 Y:2011 | 05 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,473 | $16,265 | Not Implemented |
UD0832 # 06 Y:2011 | 06 | 2011 | UPGRADE OBSOLETE EQUIPMENT | $4,243 | $4,728 | Implemented |
UD0832 # 07 Y:2011 | 07 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $986 | $500 | Implemented |
UD0832 # 08 Y:2011 | 08 | 2011 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $5,424 | $500 | Implemented |
UD0832 # 09 Y:2011 | 09 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $25,624 | $5,000 | Not Implemented |
UD0832 # 10 Y:2011 | 10 | 2011 | REPAIR OR REPLACE STEAM TRAPS | $14,246 | $2,000 | Not Implemented |
UD0832 # 11 Y:2011 | 11 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $11,335 | $2,620 | Not Implemented |
UD0832 # 12 Y:2011 | 12 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,554 | $5,000 | Not Implemented |
LL0296 # 01 Y:2008 | 01 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $463,124 | $9,955 | Not Implemented |
LL0296 # 02 Y:2008 | 02 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $116,005 | $24,680 | Implemented |
LL0296 # 03 Y:2008 | 03 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $93,199 | $40,662 | Not Implemented |
LL0296 # 04 Y:2008 | 04 | 2008 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $12,169 | $2,120 | Implemented |
LL0296 # 05 Y:2008 | 05 | 2008 | INSULATE BARE EQUIPMENT | $4,739 | $3,400 | Not Implemented |
LL0296 # 06 Y:2008 | 06 | 2008 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $3,670 | $3,894 | Not Implemented |
LL0296 # 07 Y:2008 | 07 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,916 | $1,750 | Implemented |
DL0018 # 01 Y:2008 | 01 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $425,000 | $120,000 | Implemented |