Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,415
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0820 # 07 Y:2010 | 07 | 2010 | INSTALL OCCUPANCY SENSORS | $50 | $45 | Not Implemented |
UD0820 # 08 Y:2010 | 08 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $535 | $500 | Implemented |
UD0820 # 09 Y:2010 | 09 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $513 | $1,580 | Implemented |
UD0820 # 10 Y:2010 | 10 | 2010 | IMPROVE COMBUSTION CONTROL CAPABILITY | $17,532 | $7,000 | Implemented |
UD0820 # 11 Y:2010 | 11 | 2010 | INSULATE BARE EQUIPMENT | $3,075 | $8,700 | Not Implemented |
UD0820 # 12 Y:2010 | 12 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $34,849 | $39,289 | Not Implemented |
UD0820 # 13 Y:2010 | 13 | 2010 | REPLACE AIR CURTAIN DOORS WITH SOLID DOORS | $7,994 | $45,000 | Not Implemented |
UD0820 # 14 Y:2010 | 14 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $4,962 | $4,550 | Implemented |
NC0411 # 01 Y:2010 | 01 | 2010 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $6,139 | $5,000 | Implemented |
NC0411 # 02 Y:2010 | 02 | 2010 | UPGRADE CONTROLS ON COMPRESSORS | $15,453 | $30,000 | Not Implemented |
NC0411 # 03 Y:2010 | 03 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,708 | $500 | Implemented |
NC0411 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,307 | $100 | Implemented |
NC0411 # 05 Y:2010 | 05 | 2010 | USE POWER DURING OFF-PEAK PERIODS | $400 | $100 | Implemented |
TT0055 # 01 Y:2010 | 01 | 2010 | REDUCE VENTILATION AIR | $5,009 | $17,120 | Not Implemented |
TT0055 # 02 Y:2010 | 02 | 2010 | OPTIMIZE PLANT POWER FACTOR | $11,430 | $13,000 | Implemented |
TT0055 # 03 Y:2010 | 03 | 2010 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $560 | $825 | Implemented |
TT0055 # 04 Y:2010 | 04 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,500 | $632 | Not Implemented |
TT0055 # 05 Y:2010 | 05 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $520 | $15 | Implemented |
TT0055 # 06 Y:2010 | 06 | 2010 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $253 | $250 | Implemented |
TT0055 # 07 Y:2010 | 07 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,024 | $40 | Implemented |
GT0873 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,353 | $0 | Implemented |
GT0873 # 02 Y:2010 | 02 | 2010 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $10,144 | $4,600 | Not Implemented |
GT0873 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,825 | $19,768 | Not Implemented |
GT0873 # 04 Y:2010 | 04 | 2010 | INSTALL OCCUPANCY SENSORS | $3,777 | $10,640 | Implemented |
GT0873 # 05 Y:2010 | 05 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $816 | $4,400 | Implemented |