Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,415
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0332 # 08 Y:2006 | 08 | 2006 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,280 | $0 | Not Implemented |
WV0332 # 09 Y:2006 | 09 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $955 | $190 | Not Implemented |
WV0332 # 10 Y:2006 | 10 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $411 | $150 | Not Implemented |
WV0332 # 11 Y:2006 | 11 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $214 | $123 | Not Implemented |
WI0507 # 01 Y:2006 | 01 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,310 | $23,700 | Not Implemented |
WI0507 # 02 Y:2006 | 02 | 2006 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $10,309 | $13,000 | Implemented |
WI0507 # 03 Y:2006 | 03 | 2006 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $10,121 | $2,000 | Implemented |
WI0507 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,441 | $11,565 | Implemented |
WI0507 # 05 Y:2006 | 05 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,601 | $338 | Implemented |
WI0507 # 06 Y:2006 | 06 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,034 | $30 | Implemented |
WI0507 # 07 Y:2006 | 07 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $856 | $400 | Not Implemented |
WI0507 # 08 Y:2006 | 08 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $688 | $1,280 | Implemented |
WI0507 # 09 Y:2006 | 09 | 2006 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $444 | $200 | Implemented |
BD0300 # 01 Y:2006 | 01 | 2006 | INSULATE BARE EQUIPMENT | $6,218 | $2,772 | Implemented |
BD0300 # 02 Y:2006 | 02 | 2006 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $5,526 | $500 | Implemented |
BD0300 # 03 Y:2006 | 03 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,234 | $4,000 | Not Implemented |
BD0300 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,237 | $5,115 | Implemented |
BD0300 # 05 Y:2006 | 05 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $963 | $3,450 | Not Implemented |
BD0300 # 06 Y:2006 | 06 | 2006 | INSTALL OCCUPANCY SENSORS | $508 | $825 | Not Implemented |
BD0300 # 07 Y:2006 | 07 | 2006 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $464 | $1,000 | Not Implemented |
BD0300 # 08 Y:2006 | 08 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $188 | $250 | Implemented |
BD0300 # 09 Y:2006 | 09 | 2006 | INSTALL EQUIPMENT TO MOVE PRODUCT | $18,720 | $17,500 | Not Implemented |
MA0592 # 01 Y:2006 | 01 | 2006 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $74,191 | $368,500 | Not Implemented |
MA0592 # 02 Y:2006 | 02 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $56,494 | $73,748 | Implemented |
MA0592 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $33,861 | $138,775 | Not Implemented |