Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,054
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0718 # 01 Y:2005 | 01 | 2005 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $409,000 | $15,000 | Not Implemented |
UD0718 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $77,400 | $62,900 | Not Implemented |
UD0718 # 03 Y:2005 | 03 | 2005 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $64,584 | $200,000 | Implemented |
UD0718 # 04 Y:2005 | 04 | 2005 | INSULATE BARE EQUIPMENT | $42,615 | $44,322 | Not Implemented |
UD0718 # 05 Y:2005 | 05 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $45,734 | $178,576 | Not Implemented |
UD0718 # 06 Y:2005 | 06 | 2005 | REDUCE VENTILATION AIR | $37,367 | $19,721 | Not Implemented |
UD0718 # 07 Y:2005 | 07 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19,025 | $13,430 | Not Implemented |
UD0718 # 08 Y:2005 | 08 | 2005 | USE PHOTOCELL CONTROLS | $4,300 | $12,500 | Not Implemented |
UD0718 # 09 Y:2005 | 09 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,805 | $2,598 | Not Implemented |
UD0718 # 10 Y:2005 | 10 | 2005 | USE POWER DURING OFF-PEAK PERIODS | $2,913 | $0 | Not Implemented |
UD0718 # 11 Y:2005 | 11 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,522 | $3,044 | Implemented |
UD0718 # 12 Y:2005 | 12 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $762 | $362 | Not Implemented |
WV0309 # 01 Y:2005 | 01 | 2005 | INSULATE BARE EQUIPMENT | $9,618 | $1,147 | Implemented |
WV0309 # 02 Y:2005 | 02 | 2005 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,338 | $550 | Implemented |
WV0309 # 03 Y:2005 | 03 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,461 | $760 | Implemented |
WV0309 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,239 | $8,590 | Implemented |
WV0309 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,140 | $98 | Implemented |
WV0309 # 06 Y:2005 | 06 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,646 | $232 | Implemented |
WV0309 # 07 Y:2005 | 07 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,551 | $19 | Implemented |
WV0309 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $1,334 | $1,436 | Not Implemented |
WV0309 # 09 Y:2005 | 09 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,138 | $0 | Implemented |
WV0309 # 10 Y:2005 | 10 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,066 | $507 | Implemented |
WV0309 # 11 Y:2005 | 11 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $1,012 | $133 | Implemented |
WV0309 # 12 Y:2005 | 12 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $512 | $480 | Not Implemented |
WV0309 # 13 Y:2005 | 13 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $374 | $0 | Not Implemented |