Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
208
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0388 # 03 Y:2009 | 03 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,091 | $100 | Implemented |
NC0388 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,810 | $0 | Implemented |
NC0388 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $99 | $150 | Implemented |
NC0388 # 06 Y:2009 | 06 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $995 | $160 | Implemented |
NC0388 # 07 Y:2009 | 07 | 2009 | DEVELOP A REPAIR/REPLACE POLICY | $5,653 | $8,935 | Implemented |
NC0313 # 01 Y:2005 | 01 | 2005 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $9,148 | $15,000 | Not Implemented |
NC0313 # 02 Y:2005 | 02 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $17,625 | $50,000 | Not Implemented |
NC0313 # 03 Y:2005 | 03 | 2005 | ADJUST BURNERS FOR EFFICIENT OPERATION | $10,261 | $2,000 | Implemented |
NC0313 # 04 Y:2005 | 04 | 2005 | USE MINIMUM STEAM OPERATING PRESSURE | $7,578 | $200 | Not Implemented |
NC0313 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $274 | $100 | Implemented |
NC0305 # 01 Y:2004 | 01 | 2004 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $36,051 | $3,500 | Not Implemented |
NC0305 # 02 Y:2004 | 02 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $6,108 | $200 | Not Implemented |
NC0305 # 03 Y:2004 | 03 | 2004 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,452 | $2,000 | Not Implemented |
NC0305 # 04 Y:2004 | 04 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,897 | $2,750 | Not Implemented |
NC0305 # 05 Y:2004 | 05 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $2,802 | $1,000 | Not Implemented |
NC0305 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $349 | $100 | Implemented |
NC0305 # 07 Y:2004 | 07 | 2004 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $320 | $58 | Implemented |
NC0299 # 01 Y:2004 | 01 | 2004 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $418,000 | $275,000 | Implemented |
NC0299 # 02 Y:2004 | 02 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $38,998 | $1,000 | Implemented |
NC0299 # 03 Y:2004 | 03 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $1,352 | $1,030 | Implemented |
NC0299 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,143 | $1,622 | Implemented |
NC0299 # 05 Y:2004 | 05 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,382 | $9,255 | Not Implemented |
NC0299 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $373 | $100 | Implemented |
NC0299 # 07 Y:2004 | 07 | 2004 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $895 | $2,195 | Implemented |
NC0276 # 01 Y:2004 | 01 | 2004 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $13,019 | $18,000 | Not Implemented |