Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
203
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0805 # 07 Y:2005 | 07 | 2005 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $11,117 | $10,000 | Not Implemented |
GT0805 # 08 Y:2005 | 08 | 2005 | REDESIGN PROCESS | $74,195 | $46,000 | Not Implemented |
GT0801 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,040 | $32,725 | Implemented |
GT0801 # 02 Y:2005 | 02 | 2005 | USE PHOTOCELL CONTROLS | $7,520 | $32,480 | Not Implemented |
GT0801 # 03 Y:2005 | 03 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $72 | $0 | Implemented |
GT0801 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $775 | $500 | Implemented |
GT0801 # 05 Y:2005 | 05 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,820 | $500 | Not Implemented |
GT0801 # 06 Y:2005 | 06 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,780 | $7,500 | Not Implemented |
GT0801 # 07 Y:2005 | 07 | 2005 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $35,100 | $15,000 | Implemented |
GT0801 # 08 Y:2005 | 08 | 2005 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $11,320 | $10,000 | Not Implemented |
GT0801 # 09 Y:2005 | 09 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,950 | $6,600 | Not Implemented |
GT0801 # 10 Y:2005 | 10 | 2005 | COMBINE UTILITY METERS | $12,370 | $0 | Not Implemented |
GT0797 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,893 | $3,800 | Implemented |
GT0797 # 02 Y:2005 | 02 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $22,440 | $1,500 | Implemented |
GT0797 # 03 Y:2005 | 03 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $121,511 | $243,073 | Implemented |
GT0797 # 04 Y:2005 | 04 | 2005 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $8,210 | $17,150 | Not Implemented |
GT0797 # 05 Y:2005 | 05 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,100 | $500 | Implemented |
GT0797 # 06 Y:2005 | 06 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,716 | $400 | Implemented |
GT0797 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,447 | $3,692 | Implemented |
GT0781 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $77 | $0 | Implemented |
GT0781 # 02 Y:2004 | 02 | 2004 | USE POWER DURING OFF-PEAK PERIODS | $580 | $450 | Implemented |
GT0781 # 03 Y:2004 | 03 | 2004 | DISCONNECT BALLASTS | $4,110 | $2,750 | Implemented |
GT0781 # 04 Y:2004 | 04 | 2004 | CONVERT TO INDIRECT TEMPERATURE CONTROL SYSTEM | $53,600 | $66,000 | Not Implemented |
GT0781 # 05 Y:2004 | 05 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $740 | $1,000 | Implemented |
GT0781 # 06 Y:2004 | 06 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $9,700 | $14,600 | Not Implemented |