Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,003
matching recommendationsNAICS | 3261 | Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0588 # 01 Y:2006 | 01 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $17,610 | $9,470 | Implemented |
CO0588 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,500 | $50 | Implemented |
CO0588 # 03 Y:2006 | 03 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,244 | $493 | Implemented |
CO0588 # 04 Y:2006 | 04 | 2006 | INSULATE BARE EQUIPMENT | $200 | $510 | Implemented |
CO0588 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $42,290 | $57,670 | Implemented |
CO0588 # 06 Y:2006 | 06 | 2006 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $1,680 | $1,310 | Implemented |
CO0588 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,600 | $2,970 | Implemented |
MI0133 # 02 Y:2006 | 02 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $34,704 | $0 | Implemented |
MI0133 # 04 Y:2006 | 04 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,584 | $964 | Implemented |
MI0133 # 05 Y:2006 | 05 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,755 | $30 | Implemented |
MI0132 # 01 Y:2006 | 01 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $49 | $2,342 | Implemented |
MI0132 # 02 Y:2006 | 02 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $889 | $0 | Implemented |
MI0132 # 03 Y:2006 | 03 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $222 | $1,732 | Implemented |
SU0236 # 03 Y:2006 | 03 | 2006 | INSTALL OCCUPANCY SENSORS | $868 | $127 | Implemented |
SU0236 # 04 Y:2006 | 04 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,245 | $713 | Implemented |
SU0236 # 05 Y:2006 | 05 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $1,176 | $365 | Implemented |
SU0236 # 06 Y:2006 | 06 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $758 | $220 | Implemented |
SU0236 # 07 Y:2006 | 07 | 2006 | INSTALL DESICCANT HUMIDITY CONTROL SYSTEM | $65,227 | $70,000 | Implemented |
SU0236 # 08 Y:2006 | 08 | 2006 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,279 | $2,517 | Implemented |
SU0236 # 10 Y:2006 | 10 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,858 | $12,200 | Implemented |
SD0381 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,290 | $320 | Implemented |
SD0381 # 04 Y:2006 | 04 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $2,044 | $146 | Implemented |
SD0381 # 06 Y:2006 | 06 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $305 | $0 | Implemented |
MI0130 # 01 Y:2006 | 01 | 2006 | REDESIGN PROCESS | $7,148 | $580 | Implemented |
MI0130 # 02 Y:2006 | 02 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,958 | $202 | Implemented |