Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
166
matching recommendationsNAICS | 3261 | Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0797 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,893 | $3,800 | Implemented |
GT0797 # 02 Y:2005 | 02 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $22,440 | $1,500 | Implemented |
GT0797 # 03 Y:2005 | 03 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $121,511 | $243,073 | Implemented |
GT0797 # 04 Y:2005 | 04 | 2005 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $8,210 | $17,150 | Not Implemented |
GT0797 # 05 Y:2005 | 05 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,100 | $500 | Implemented |
GT0797 # 06 Y:2005 | 06 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,716 | $400 | Implemented |
GT0797 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,447 | $3,692 | Implemented |
GT0781 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $77 | $0 | Implemented |
GT0781 # 02 Y:2004 | 02 | 2004 | USE POWER DURING OFF-PEAK PERIODS | $580 | $450 | Implemented |
GT0781 # 03 Y:2004 | 03 | 2004 | DISCONNECT BALLASTS | $4,110 | $2,750 | Implemented |
GT0781 # 04 Y:2004 | 04 | 2004 | CONVERT TO INDIRECT TEMPERATURE CONTROL SYSTEM | $53,600 | $66,000 | Not Implemented |
GT0781 # 05 Y:2004 | 05 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $740 | $1,000 | Implemented |
GT0781 # 06 Y:2004 | 06 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $9,700 | $14,600 | Not Implemented |
GT0781 # 07 Y:2004 | 07 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $98,900 | $253,400 | Not Implemented |
GT0781 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,408 | $7,300 | Implemented |
GT0786 # 01 Y:2004 | 01 | 2004 | MAINTAIN MACHINES TO REDUCE LEAKS | $121,900 | $45,000 | Implemented |
GT0786 # 02 Y:2004 | 02 | 2004 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $33,950 | $38,000 | Not Implemented |
GT0786 # 03 Y:2004 | 03 | 2004 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $33,280 | $25,000 | Not Implemented |
GT0786 # 04 Y:2004 | 04 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $27,700 | $22,500 | Not Implemented |
GT0786 # 05 Y:2004 | 05 | 2004 | CLEAN CONDENSER TUBES | $22,690 | $3,000 | Implemented |
GT0786 # 06 Y:2004 | 06 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $19,500 | $0 | Not Implemented |
GT0786 # 07 Y:2004 | 07 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $4,600 | $35 | Implemented |
GT0786 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,040 | $3,737 | Not Implemented |
GT0782 # 01 Y:2004 | 01 | 2004 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $7,120 | $5,800 | Not Implemented |
GT0782 # 02 Y:2004 | 02 | 2004 | BURN A LESS EXPENSIVE GRADE OF FUEL | $9,340 | $2,000 | Not Implemented |