Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
88
matching recommendationsNAICS | 3261 | Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LS2206 # 06 Y:2022 | 06 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,272 | $2,688 | Implemented |
LS2206 # 05 Y:2022 | 05 | 2022 | INSTALL OCCUPANCY SENSORS | $21 | $25 | Not Implemented |
LS2206 # 04 Y:2022 | 04 | 2022 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $336 | $250 | Implemented |
LS2206 # 03 Y:2022 | 03 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,034 | $630 | Implemented |
LS2206 # 01 Y:2022 | 01 | 2022 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $1,066 | $10 | Implemented |
LS2206 # 02 Y:2022 | 02 | 2022 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,014 | $25 | Implemented |
LS2103 # 03 Y:2021 | 03 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,440 | $900 | Implemented |
LS2103 # 01 Y:2021 | 01 | 2021 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $35,907 | $250 | Implemented |
LS2103 # 05 Y:2021 | 05 | 2021 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $209,892 | $1,023,215 | Implemented |
LS2103 # 02 Y:2021 | 02 | 2021 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,807 | $428 | Implemented |
LS2103 # 04 Y:2021 | 04 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,154 | $39,829 | Implemented |
LS2006 # 07 Y:2020 | 07 | 2020 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $9,737 | $81,000 | Not Implemented |
LS2006 # 03 Y:2020 | 03 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,740 | $0 | Implemented |
LS2006 # 06 Y:2020 | 06 | 2020 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,553 | $7,413 | Not Implemented |
LS2006 # 02 Y:2020 | 02 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,970 | $1,800 | Implemented |
LS2006 # 04 Y:2020 | 04 | 2020 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $566 | $375 | Implemented |
LS2006 # 01 Y:2020 | 01 | 2020 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $796 | $300 | Implemented |
LS2006 # 05 Y:2020 | 05 | 2020 | INSTALL OCCUPANCY SENSORS | $31 | $45 | Not Implemented |
LS2005 # 05 Y:2020 | 05 | 2020 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $274 | $0 | Implemented |
LS2005 # 01 Y:2020 | 01 | 2020 | INSTALL TIMERS AND/OR THERMOSTATS | $2,727 | $300 | Not Implemented |
LS2005 # 06 Y:2020 | 06 | 2020 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $225,476 | $1,204,486 | Not Implemented |
LS2005 # 03 Y:2020 | 03 | 2020 | INSTALL OCCUPANCY SENSORS | $114 | $50 | Not Implemented |
LS2005 # 02 Y:2020 | 02 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,560 | $0 | Implemented |
LS2005 # 04 Y:2020 | 04 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $30,208 | $17,766 | Not Implemented |
AM0613 # 06 Y:2012 | 06 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $694 | $108 | Implemented |