Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
45
matching recommendationsNAICS | 326111 | Plastics Bag and Pouch Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0269 # 07 Y:2003 | 07 | 2003 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $14,907 | $640 | Not Implemented |
NC0269 # 06 Y:2003 | 06 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,654 | $2,400 | Implemented |
NC0269 # 05 Y:2003 | 05 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,908 | $800 | Not Implemented |
NC0269 # 04 Y:2003 | 04 | 2003 | DEVELOP A REPAIR/REPLACE POLICY | $4,027 | $1,719 | Implemented |
NC0269 # 03 Y:2003 | 03 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $14,974 | $9,174 | Implemented |
NC0269 # 02 Y:2003 | 02 | 2003 | INSULATE BARE EQUIPMENT | $16,965 | $5,128 | Implemented |
NC0269 # 01 Y:2003 | 01 | 2003 | INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT | $272,200 | $118,250 | Implemented |
NC0260 # 02 Y:2003 | 02 | 2003 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $19,437 | $8,000 | Not Implemented |
NC0260 # 09 Y:2003 | 09 | 2003 | USE PHOTOCELL CONTROLS | $806 | $550 | Not Implemented |
NC0260 # 08 Y:2003 | 08 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $264 | $252 | Not Implemented |
NC0260 # 07 Y:2003 | 07 | 2003 | DEVELOP A REPAIR/REPLACE POLICY | $347 | $260 | Not Implemented |
NC0260 # 06 Y:2003 | 06 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $234 | $0 | Not Implemented |
NC0260 # 05 Y:2003 | 05 | 2003 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $11,263 | $16,548 | Not Implemented |
NC0260 # 04 Y:2003 | 04 | 2003 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $606 | $176 | Not Implemented |
NC0260 # 03 Y:2003 | 03 | 2003 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $16,074 | $9,000 | Not Implemented |
NC0260 # 01 Y:2003 | 01 | 2003 | INSTALL OCCUPANCY SENSORS | $396 | $208 | Not Implemented |
NC0261 # 08 Y:2003 | 08 | 2003 | MODIFY CURRENT INCENTIVE PROGRAM | $406,000 | $41,000 | Not Implemented |
NC0261 # 07 Y:2003 | 07 | 2003 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $910 | $3,948 | Not Implemented |
NC0261 # 06 Y:2003 | 06 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,314 | $500 | Not Implemented |
NC0261 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,466 | $6,430 | Implemented |
NC0261 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,891 | $50 | Implemented |
NC0261 # 03 Y:2003 | 03 | 2003 | INSULATE BARE EQUIPMENT | $13,615 | $5,261 | Not Implemented |
NC0261 # 02 Y:2003 | 02 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $17,622 | $2,911 | Not Implemented |
NC0261 # 01 Y:2003 | 01 | 2003 | DEVELOP A REPAIR/REPLACE POLICY | $10,483 | $9,992 | Implemented |
NC0259 # 08 Y:2003 | 08 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,879 | $1,740 | Implemented |