IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

486

matching recommendations
Reset
NAICS 32619 Other Plastics Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0269 # 08 Y:2003 08 2003 INSTALL OCCUPANCY SENSORS $3,716 $350 Implemented
WV0269 # 09 Y:2003 09 2003 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $19,656 $690 Implemented
WV0269 # 10 Y:2003 10 2003 RECOVER WASTE HEAT FROM EQUIPMENT $36,459 $6,156 Not Implemented
UD0670 # 01 Y:2003 01 2003 RECOVER WASTE HEAT FROM EQUIPMENT $9,320 $4,000 Not Implemented
UD0670 # 02 Y:2003 02 2003 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $7,300 $5,520 Not Implemented
UD0670 # 03 Y:2003 03 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,440 $20,540 Implemented
UD0670 # 04 Y:2003 04 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,218 $0 Implemented
UD0670 # 05 Y:2003 05 2003 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,644 $3,620 Not Implemented
UD0670 # 06 Y:2003 06 2003 DISCONNECT BALLASTS $1,597 $144 Implemented
UD0670 # 07 Y:2003 07 2003 DISCONNECT BALLASTS $1,367 $70 Implemented
UD0670 # 08 Y:2003 08 2003 INSTALL TIMERS AND/OR THERMOSTATS $1,243 $2,500 Not Implemented
UD0670 # 09 Y:2003 09 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $813 $1,458 Implemented
UD0670 # 10 Y:2003 10 2003 INSULATE BARE EQUIPMENT $730 $160 Not Implemented
UD0667 # 01 Y:2003 01 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,330 $21,177 Not Implemented
UD0667 # 02 Y:2003 02 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,500 $13,580 Not Implemented
UD0667 # 03 Y:2003 03 2003 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $3,794 $0 Not Implemented
UD0667 # 04 Y:2003 04 2003 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,541 $0 Not Implemented
UD0667 # 05 Y:2003 05 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,175 $0 Implemented
UD0667 # 06 Y:2003 06 2003 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,040 $0 Not Implemented
UD0667 # 07 Y:2003 07 2003 INSTALL OCCUPANCY SENSORS $150 $212 Not Implemented
UD0666 # 01 Y:2003 01 2003 USE POWER DURING OFF-PEAK PERIODS $21,034 $0 Implemented
UD0666 # 02 Y:2003 02 2003 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $16,698 $0 Implemented
UD0666 # 03 Y:2003 03 2003 HIRE ADDITIONAL PERSONNEL TO REDUCE CHANGEOUT TIME $14,700 $0 Implemented
UD0666 # 04 Y:2003 04 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,180 $0 Not Implemented
UD0666 # 05 Y:2003 05 2003 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $3,885 $0 Implemented