Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
124
matching recommendationsNAICS | 326191 | Plastics Plumbing Fixture Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0026 # 07 Y:2008 | 07 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,048 | $0 | Implemented |
MI0130 # 01 Y:2006 | 01 | 2006 | REDESIGN PROCESS | $7,148 | $580 | Implemented |
MI0130 # 02 Y:2006 | 02 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,958 | $202 | Implemented |
MI0130 # 03 Y:2006 | 03 | 2006 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $4,791 | $1,020 | Implemented |
MI0130 # 04 Y:2006 | 04 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,865 | $1,074 | Implemented |
MI0130 # 05 Y:2006 | 05 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,043 | $720 | Not Implemented |
MI0130 # 06 Y:2006 | 06 | 2006 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $1,895 | $3,800 | Implemented |
MI0130 # 07 Y:2006 | 07 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,650 | $30 | Not Implemented |
GT0805 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $310 | $253 | Not Implemented |
GT0805 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,451 | $3,470 | Not Implemented |
GT0805 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,375 | $5,705 | Not Implemented |
GT0805 # 04 Y:2005 | 04 | 2005 | DISCONNECT BALLASTS | $1,400 | $700 | Not Implemented |
GT0805 # 05 Y:2005 | 05 | 2005 | COMBINE UTILITY METERS | $4,682 | $7,000 | Not Implemented |
GT0805 # 06 Y:2005 | 06 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $23,800 | $0 | Not Implemented |
GT0805 # 07 Y:2005 | 07 | 2005 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $11,117 | $10,000 | Not Implemented |
GT0805 # 08 Y:2005 | 08 | 2005 | REDESIGN PROCESS | $74,195 | $46,000 | Not Implemented |
SD0361 # 01 Y:2005 | 01 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,131 | $15,000 | Not Implemented |
SD0361 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,570 | $280 | Implemented |
SD0361 # 03 Y:2005 | 03 | 2005 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,916 | $144 | Implemented |
SD0361 # 04 Y:2005 | 04 | 2005 | INSTALL OCCUPANCY SENSORS | $390 | $170 | Implemented |
SD0361 # 05 Y:2005 | 05 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $42,000 | $18,500 | Not Implemented |
SD0358 # 01 Y:2005 | 01 | 2005 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $10,212 | $3,850 | Not Implemented |
SD0358 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,194 | $360 | Implemented |
SD0358 # 03 Y:2005 | 03 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $980 | $76 | Not Implemented |
SD0358 # 04 Y:2005 | 04 | 2005 | LOWER OPERATING PRESSURE OF CONDENSER (STEAM) | $593 | $0 | Not Implemented |