Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
757
matching recommendationsNAICS | 32721 | Glass and Glass Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0693 # 02 Y:2004 | 02 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $28,651 | $88,297 | Not Implemented |
OK0693 # 03 Y:2004 | 03 | 2004 | OPTIMIZE PLANT POWER FACTOR | $7,010 | $10,720 | n/a |
OK0693 # 04 Y:2004 | 04 | 2004 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $2,179 | $3,635 | Not Implemented |
OK0693 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,903 | $31,913 | Implemented |
OK0693 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $808 | $123 | Not Implemented |
OK0693 # 07 Y:2004 | 07 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $992 | $1,025 | Not Implemented |
OK0693 # 08 Y:2004 | 08 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $772 | $1,140 | Implemented |
OK0693 # 09 Y:2004 | 09 | 2004 | INSTALL OCCUPANCY SENSORS | $356 | $737 | Implemented |
MI0088 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,029 | $0 | Not Implemented |
MI0088 # 02 Y:2004 | 02 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $28,772 | $2,300 | Implemented |
MI0088 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $-1,117 | $750 | Implemented |
MI0088 # 04 Y:2004 | 04 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $22,760 | $40,140 | Implemented |
MI0088 # 05 Y:2004 | 05 | 2004 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $427,935 | $0 | Implemented |
MI0088 # 06 Y:2004 | 06 | 2004 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $17,529 | $0 | Not Implemented |
MI0088 # 07 Y:2004 | 07 | 2004 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $14,310 | $0 | Not Implemented |
MI0088 # 08 Y:2004 | 08 | 2004 | PAY BILLS ON TIME TO AVOID LATE FEES | $770 | $0 | Implemented |
LM0077 # 01 Y:2004 | 01 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,750 | $3,825 | Not Implemented |
LM0077 # 02 Y:2004 | 02 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $117 | $0 | Implemented |
LM0077 # 03 Y:2004 | 03 | 2004 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $91 | $100 | Implemented |
LM0077 # 04 Y:2004 | 04 | 2004 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $36,400 | $8,800 | Not Implemented |
LM0077 # 05 Y:2004 | 05 | 2004 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $812 | $0 | Implemented |
LM0077 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $997 | $1,920 | Not Implemented |
LL0190 # 01 Y:2004 | 01 | 2004 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $52,925 | $8,000 | Implemented |
LL0190 # 02 Y:2004 | 02 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $27,961 | $1,024 | Not Implemented |
LL0190 # 03 Y:2004 | 03 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,878 | $2,070 | Implemented |