Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
50
matching recommendationsNAICS | 327215 | Glass Product Manufacturing Made of Purchased Glass |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0112 # 02 Y:2005 | 02 | 2005 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $89,581 | $90 | Implemented |
MI0112 # 01 Y:2005 | 01 | 2005 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $319,237 | $91,320 | Not Implemented |
MI0112 # 05 Y:2005 | 05 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,504 | $1,393 | Implemented |
MI0112 # 04 Y:2005 | 04 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $6,289 | $600 | Implemented |
MI0112 # 03 Y:2005 | 03 | 2005 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $19,066 | $8,226 | Implemented |
IA0365 # 04 Y:2005 | 04 | 2005 | INSTALL OCCUPANCY SENSORS | $1,148 | $1,001 | Not Implemented |
IA0365 # 08 Y:2005 | 08 | 2005 | HIRE ADDITIONAL PERSONNEL TO REDUCE CHANGEOUT TIME | $21,000 | $7,216 | Implemented |
IA0365 # 07 Y:2005 | 07 | 2005 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $11,495 | $14,000 | Not Implemented |
IA0365 # 06 Y:2005 | 06 | 2005 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $1,000,000 | $152,672 | Implemented |
IA0365 # 05 Y:2005 | 05 | 2005 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $628 | $1,600 | Implemented |
IA0365 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,995 | $3,000 | Implemented |
IA0365 # 02 Y:2005 | 02 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $779 | $19 | Implemented |
IA0365 # 01 Y:2005 | 01 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,317 | $50 | Implemented |
MI0102 # 02 Y:2005 | 02 | 2005 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $66,212 | $29,320 | Not Implemented |
MI0102 # 01 Y:2005 | 01 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $100,313 | $40,224 | Not Implemented |
MI0102 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,049 | $870 | Not Implemented |
MI0102 # 04 Y:2005 | 04 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,890 | $162 | Not Implemented |
MI0102 # 03 Y:2005 | 03 | 2005 | REDUCE DEFECTS BY REDUCING PRODUCT TIPPING | $23,325 | $1,104 | Not Implemented |
CO0558 # 02 Y:2004 | 02 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,700 | $2,720 | Implemented |
CO0558 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,660 | $7,410 | Implemented |
CO0558 # 05 Y:2004 | 05 | 2004 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,810 | $1,910 | Not Implemented |
CO0558 # 04 Y:2004 | 04 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $234 | $588 | Implemented |
CO0558 # 03 Y:2004 | 03 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,020 | $6,030 | Implemented |
CO0558 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,990 | $350 | Implemented |
MI0088 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,029 | $0 | Not Implemented |