Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

450

matching recommendations
Reset
NAICS 3279 Other Nonmetallic Mineral Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AS0428 # 08 Y:2006 08 2006 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $475 $4,000 n/a
AS0429 # 01 Y:2006 01 2006 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,688 $1,000 n/a
AS0429 # 02 Y:2006 02 2006 INSULATE BARE EQUIPMENT $2,039 $500 n/a
AS0429 # 03 Y:2006 03 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,127 $1,000 n/a
AS0429 # 04 Y:2006 04 2006 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $34 $3,200 n/a
OK0716 # 01 Y:2005 01 2005 OPTIMIZE PLANT POWER FACTOR $10,863 $38,544 Not Implemented
OK0716 # 02 Y:2005 02 2005 $1,900 $200 Not Implemented
OK0716 # 03 Y:2005 03 2005 $-28,676 $0 Not Implemented
OK0716 # 04 Y:2005 04 2005 USE PHOTOCELL CONTROLS $1,725 $125 Not Implemented
OK0716 # 05 Y:2005 05 2005 INSTALL OCCUPANCY SENSORS $212 $475 Not Implemented
OK0716 # 06 Y:2005 06 2005 INSTALL TIMERS AND/OR THERMOSTATS $579 $25 Not Implemented
OK0716 # 07 Y:2005 07 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $153 $1,346 Not Implemented
MA0584 # 01 Y:2005 01 2005 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $6,369 $2,100 Implemented
MA0584 # 02 Y:2005 02 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,880 $2,800 Implemented
MA0584 # 03 Y:2005 03 2005 USE RADIANT HEATER FOR SPOT HEATING $3,727 $11,326 Not Implemented
MA0584 # 04 Y:2005 04 2005 INSULATE BARE EQUIPMENT $2,152 $1,400 Implemented
MA0584 # 05 Y:2005 05 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,098 $9,400 Not Implemented
WI0483 # 01 Y:2005 01 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,449 $18,810 n/a
WI0483 # 02 Y:2005 02 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $7,950 $10,000 Not Implemented
WI0483 # 03 Y:2005 03 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,804 $500 Not Implemented
WI0483 # 04 Y:2005 04 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $6,164 $830 Implemented
WI0483 # 05 Y:2005 05 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,971 $2,186 Not Implemented
WI0483 # 06 Y:2005 06 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,886 $0 Not Implemented
WI0483 # 07 Y:2005 07 2005 INSULATE BARE EQUIPMENT $393 $40 Not Implemented
WV0306 # 01 Y:2004 01 2004 PREHEAT COMBUSTION AIR WITH WASTE HEAT $30,489 $20,910 Not Implemented