Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
306
matching recommendationsNAICS | 331 | Primary Metal Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0413 # 05 Y:2008 | 05 | 2008 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $14,800 | $1,117 | Implemented |
UF0413 # 06 Y:2008 | 06 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $13,321 | $13,321 | Implemented |
UF0413 # 07 Y:2008 | 07 | 2008 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $12,742 | $20,000 | Not Implemented |
UF0413 # 08 Y:2008 | 08 | 2008 | INSTALL COMMON HEADER ON COMPRESSORS | $871 | $2,000 | Implemented |
UF0413 # 09 Y:2008 | 09 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $151,840 | $16,695 | Not Implemented |
UF0413 # 10 Y:2008 | 10 | 2008 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $9,571 | $1,500 | Not Implemented |
UW0018 # 01 Y:2008 | 01 | 2008 | $55,734 | $72,000 | Not Implemented | |
UW0018 # 03 Y:2008 | 03 | 2008 | USE OPTIMUM THICKNESS INSULATION | $9,391 | $39,900 | Not Implemented |
UW0018 # 04 Y:2008 | 04 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,375 | $4,328 | Not Implemented |
UW0018 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,037 | $2,775 | Not Implemented |
UW0018 # 02 Y:2008 | 02 | 2008 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $12,434 | $34,000 | Not Implemented |
BD0346 # 08 Y:2008 | 08 | 2008 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $4,096 | $1,251 | Not Implemented |
BD0346 # 09 Y:2008 | 09 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $19,119 | $14,001 | Not Implemented |
BD0346 # 07 Y:2008 | 07 | 2008 | REPLACE BOILER | $37,675 | $65,001 | Not Implemented |
BD0346 # 06 Y:2008 | 06 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $833 | $501 | Implemented |
BD0346 # 05 Y:2008 | 05 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $48,385 | $10,001 | Implemented |
BD0346 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $893 | $1,366 | Not Implemented |
BD0346 # 03 Y:2008 | 03 | 2008 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $4,548 | $4,569 | Not Implemented |
BD0346 # 02 Y:2008 | 02 | 2008 | INSTALL OCCUPANCY SENSORS | $1,472 | $676 | Not Implemented |
BD0346 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $84,447 | $2,972 | Implemented |
UM0338 # 01 Y:2008 | 01 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $30,146 | $38,350 | Not Implemented |
UM0338 # 02 Y:2008 | 02 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $16,908 | $4,000 | Not Implemented |
UM0338 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,301 | $19,680 | Not Implemented |
UM0338 # 04 Y:2008 | 04 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $8,640 | $1,400 | Not Implemented |
UM0338 # 05 Y:2008 | 05 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,107 | $900 | Not Implemented |