Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
668
matching recommendationsNAICS | 33122 | Rolling and Drawing of Purchased Steel |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UK1801 # 10 Y:2018 | 10 | 2018 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $3,756 | $5,475 | Not Implemented |
UK1801 # 11 Y:2018 | 11 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,054 | $0 | Not Implemented |
IP0086 # 13 Y:2017 | 13 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,424 | $31,458 | Implemented |
IP0086 # 12 Y:2017 | 12 | 2017 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,582 | $3,703 | Not Implemented |
IP0086 # 11 Y:2017 | 11 | 2017 | OPTIMIZE PLANT POWER FACTOR | $23,517 | $28,545 | Not Implemented |
IP0086 # 10 Y:2017 | 10 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $155 | $109 | Not Implemented |
IP0086 # 09 Y:2017 | 09 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,994 | $1,740 | Not Implemented |
IP0086 # 08 Y:2017 | 08 | 2017 | INSTALL OCCUPANCY SENSORS | $522 | $204 | Implemented |
IP0086 # 07 Y:2017 | 07 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $29,028 | $7,975 | Not Implemented |
IP0086 # 06 Y:2017 | 06 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,677 | $1,400 | Not Implemented |
IP0086 # 05 Y:2017 | 05 | 2017 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $12,071 | $775 | Not Implemented |
IP0086 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $137 | $8 | Implemented |
IP0086 # 03 Y:2017 | 03 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,016 | $90 | Not Implemented |
IP0086 # 02 Y:2017 | 02 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $11,932 | $4 | Not Implemented |
IP0086 # 01 Y:2017 | 01 | 2017 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,463 | $0 | Implemented |
OK0961 # 14 Y:2017 | 14 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $497,839 | $3,000,000 | Not Implemented |
OK0961 # 13 Y:2017 | 13 | 2017 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $311,801 | $1,832,665 | Not Implemented |
OK0961 # 12 Y:2017 | 12 | 2017 | REUSE RICH WHITE WATER IN OTHER APPLICATIONS | $523,580 | $500,000 | Not Implemented |
OK0961 # 11 Y:2017 | 11 | 2017 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $44,544 | $8,817 | Not Implemented |
OK0961 # 10 Y:2017 | 10 | 2017 | COVER OPEN TANKS | $27,427 | $3,900 | Not Implemented |
OK0961 # 09 Y:2017 | 09 | 2017 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $50,374 | $124,000 | Not Implemented |
OK0961 # 08 Y:2017 | 08 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $12,104 | $792 | Not Implemented |
OK0961 # 07 Y:2017 | 07 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $216,378 | $7,000 | Not Implemented |
OK0961 # 06 Y:2017 | 06 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $831 | $3,220 | Not Implemented |
OK0961 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,978 | $7,268 | Not Implemented |